VMware vCenter Server Updates & Release Notes
19 updates curated from 21 sources by the Releasebot Team. Last updated: Nov 25, 2026
- Nov 24, 2026
- Date parsed from source:Nov 24, 2026
- First seen by Releasebot:Nov 25, 2026
VMware vCenter Server by Broadcom
vSphere
VMware vCenter Server brings broad VCF 9.1.2 enhancements, including faster patching, stronger security, expanded automation and API capabilities, improved storage and memory tiering, and more efficient workload operations.
24 NOV | VCF 9.1.2 GA. For detailed dependencies and instructions on how to upgrade or patch, see VCF 9.1.2 Release Notes. This document contains the following sections Compatibility ESX New Features Installation Storage API ESX Host Client Snapshot Operations Virtual Machine Management I/O Security System Services Memory Tiering vCenter New Features vSphere Lifecycle Manager vSphere Client vCenter Content Library Storage vSphere High Availability API Snapshots Metrics Distributed Resource Scheduler Compatibility Guest Operating System Compatibility for ESX To determine which guest operating systems are compatible with ESX 9.1, see the Broadcom Compatibility Guide. The following new major guest operating system releases are supported in this release: • Ubuntu 26.04 LTS • SUSE Linux Enterprise Server 16 • Debian 13.0 • FreeBSD 15.0 • Pardus 25.0 • CentOS Stream 10 (supported as Tech Preview) • CentOS Stream 9 (supported as Tech Preview) Support for the following guest operating system releases is deprecated or terminated in this release: • RHEL 4.x: Terminated • Oracle Linux 5.x: Terminated • CentOS 4.x and 5.x: Terminated • SUSE Linux Enterprise Server 10 SP4: Terminated • SUSE Linux Enterprise Desktop 12: Terminated • Debian 7.x: Terminated • Flatcar Container Linux 3033 LTS: Terminated • Asianux 3.x: Terminated • Asianux 4.x: Deprecated Windows Guest OS Pending Reboot Reporting with VMware Tools 13.1.0: With VCF 9.1, VMware Tools 13.1.0 adds a vCenter UI and API restart status indicator that allows you to monitor and identify virtual machines with pending restarts after a VMware Tools upgrade. This status allows you to efficiently schedule the pending restarts. For more information, see Monitor the Guest Operating System Reboot Status. ESX New Features Installation Zero Touch Provisioning (ZTP) for ESX installation: VCF 9.1 introduces Zero Touch Provisioning (ZTP), using a secure UEFI and HTTPS-based network boot to provision ESX images on hosts at scale. ZTP simplifies and modernizes the way ESX hosts are installed and prepared for VCF consumption, avoiding the configuration of PXE infrastructure and the use of additional network services such as TFTP configurations. With VCF 9.1, you can boot multiple servers from a single HTTPS URL using a static network configuration on bare metal. ZTP serves as a forward-looking replacement for legacy Auto Deploy, which is deprecated in VCF 9.0. For more information, see Using Zero Touch Provisioning. Storage RDMA Observability Еnhancement: With VCF 9.1, you can use the pktcap-uw --capture RDMASniffer command for packet analysis and the rdmaperf-uw tool to validate network readiness for RDMA-based applications such as vSAN over RDMA or NVMe over RDMA. With the RDMA Sniffer capability for native packet capture and the built-in rdmaperf utility, you can troubleshoot RoCEv2 connections, verify end-to-end connectivity between nodes, and evaluate throughput and latency metrics directly within the ESX hypervisor. API Guest Customization APIs: VCF 9.1 introduces updates to the Guest Customization APIs, focusing on network configuration flexibility and improved automation: • For Powered-Off VMs: • IPv6-Only Support: You can explicitly deacivate IPv4 to configure IPv6-only networking in guest customization by both the UI and API. This capability avoids the need to maintain a parallel IPv4 configuration. • Partial Network Customization: You can customize network settings by providing only network-related fields to Guest Customization API. This capability streamlines operations by avoiding the need to supply the full customization profile when only network changes are required. • Expanded Account Management: • Linux: Adds support for setting the root account password during customization. • Windows/Linux: Adds support for resetting root (Linux) and Administrator (Windows) passwords on existing VMs. • Script Execution: Enhanced support for executing customization scripts within Windows guest environments. • For Powered-On VMs: • Live Network Customization: The Guest Customization API supports updating guest network settings for powered-on VMs. This capability facilitates real-time network changes without the need to power off the VM. ESX Host Client Updated ESX Host Client: VCF 9.1 provides improved experience in the ESX Host Client, similar to the vSphere Client, to manage compute, storage and networking at the single ESX host level. The updated ESX Host Client provides full feature parity with previous versions. Snapshot Operations Change Block Tracking (CBT) Enhancement: VCF 9.1 adds an enhancement to CBT enablement that removes the unresponsiveness of VMs during snapshot operations. The overall operation for taking a snapshot is not reduced in time, but the VM unresponsiveness is resolved, as opposed to an undefined period of unresponsiveness for VMs with larger disks before the change. Virtual Machine Management Linked Clones of First Class Disk: As of VCF 9.1, you can make linked clones of first class disk (FCD). You can use such clones for fast provisioning of container storage volumes in VMware Kubernetes Service (VKS). For more information, see Linked Clone First Class Disk. I/O Enhanced DirectPath for Operational Flexibility: • NVIDIA Mellanox ConnectX-7 and BlueField-3: ESX 9.1 adds support for NVIDIA Mellanox ConnectX-7 and BlueField-3 with Enhanced DirectPath, delivering high performance for AI/HPC workloads in passthrough architectures. This enablement elevates raw performance but also operational flexibility for using vSphere vMotion, Storage vMotion, Live Patch, and Hot-Add/Remove virtual hardware. • AMD MI350: ESX 9.1 adds support for the AMD MI350 GPU, with Enhanced DirectPath, advancing AI/HPC workloads in passthrough architectures to deliver high-performance speeds for faster training and inference. This enablement facilitates virtualization capabilities such as Live Patch, Storage vMotion, and Hot-Add/Remove virtual hardware, and enhances operational flexibility. Strategic partnerships with Hugging Face and participation in key open source consortiums (PyTorch, OPEA, UALink) ensures optimized performance and accelerate AI adoption. Support for Intel NIC E825 for Xeon Gen 6 (Granite Rapids-D): ESX 9.1 expands hardware compatibility by adding support for Intel NIC E825, which is integrated into the Intel Xeon Gen 6 (Granite Rapids-D) platform and functions as a LAN on Motherboard (LOM) NIC. IOMMU Virtualization Support for AMD Hosts with DirectPath Devices: ESX 9.1 introduces IOMMU virtualization support for AMD hosts with DirectPath devices to deliver significant performance gains and near-native hardware access for critical virtual machines while improving security and memory isolation. Security Quick Boot Support for ESX Hosts with Confidential VMs: With ESX 9.1, Quick Boot supports ESX hosts running confidential VMs, bypassing the time-consuming full power cycle and firmware initialization required by a regular reboot. Quick Boot support speeds up maintenance operations and significantly reduces the upgrade time for the ESX server. User-Level Monitor (ULM) for Enhanced Security: VCF 9.1 introduces User-Level Monitor (ULM) as the default monitor for all virtual machines. ULM completely reimplements the virtual machine monitor (VMM) for ESX. The monitor is responsible for running your virtual machines and significantly reduces the amount of hypervisor code running in privileged mode in the ESX kernel, hence reducing the potential of guest escapes compromising the host. General Availability for AMD Secure Encrypted Virtualization-Secure Nested Paging (SEV-SNP): With ESX 9.1, AMD SEV-SNP for confidential VMs is general availability, after being introduced as a limited availability release with ESX 9.0. AMD SEV-SNP provides a hardware-based Trusted Execution Environment (TEE) for critical workloads, ensuring data integrity, confidentiality, and verifiable authenticity. The latest version of SEV-SNP adds memory integrity protections to prevent hypervisor-based attacks like data re-play and memory re-mapping. The latest SEV-SNP release also enables remote attestation to ensure the integrity of confidential VMs are not compromised. It is compatible with AMD EPYC Zen 3 (Milan) and later processors. For more information, see Securing Virtual Machines with AMD Secure Encrypted Virtualization-Secure Nested Paging. General Availability for Intel Trusted Domain Extensions (TDX): With ESX 9.1, Intel TDX for confidential VMs is general availability, after being introduced as a limited availability release with ESX 9.0. Intel TDX provides a hardware-based Trusted Execution Environment (TEE) for critical workloads, ensuring data integrity, confidentiality, and verifiable authenticity through attestation. It is compatible with Intel Xeon Gen 5 (Emerald Rapids) and later processors, see Securing Virtual Machines with Intel TDX. For more information, see Securing Virtual Machines with Intel TDX. System Services Improved Syslog Service Performance: ESX 9.1 optimizes the syslog service, vmsyslogd, to handle a greater volume of logging messages for the TCP, SSL, and UDP protocols, ensuring more efficient and reliable logging in high-demand environments. This enhancement delivers improved performance and stability for system monitoring. For more information, see ESX Syslog Options. Memory Tiering Memory Tiering Configuration Enhancements: • Simplified deployment: Memory Tiering configuration, including enablement and device selection, does not require a host reboot, reducing deployment time and the maintenance window, and resulting in cost savings. • Support for all VM types: ESX 9.1 removes limitations for the types of VMs you can power on in memory tiered host, such as low-latency, security, and monster VMs. Resiliency for Memory Tiering by Using Software RAID Mirroring: ESX 9.1 improves resiliency for Memory Tiering by allowing for a mirrored device, without impacting performance. With the enablement, if a device fails, the secondary device performs memory tiering to ensure continued operations. With a second NVMe device using RAID1 mirroring, memory tiering cannot fail, regardless of NVMe device lifetime, reliability, and wear-out. vCenter New Features File integrity monitoring capability: VCF 9.1 adds a File Integrity Monitoring (FIM) capability, aligned with NIST SP 800-115, which detects changes by malware or malicious actors to static files or binaries installed by vCenter. FIM is turned on by default and runs every four hours to detect malicious or unintentional changes or corruption of the installed files . You can get a FIM report by using API or stream FIM logs to VCF Operations by using the syslog service. Pre-installed Logs Management Agent: vCenter 9.1 comes with a pre-installed Logs management agent that pushes logs to VCF Operations and persists across upgrades. For more information, see Configure Log Insight Agent to Send Custom vCenter Logs to log management. Upgrade of the vCenter Virtual Machine Hardware Version to vmx-17: With VCF 9.1, vCenter VM hardware version is upgraded from vmx-10 to vmx-17. For more information, see Manually update the vCenter VM's hardware version in vCenter 9.1 and above if its updated from 9.0. On-demand Pre-checks for RDU: With vCenter 9.1, you can run on-demand pre-checks for RDU, similar to the regular vCenter patching pre-checks. For more information, see Perform Upgrade Prechecks. Automating Download of Payloads for vCenter Reduced Downtime Upgrade (RDU): With vCenter 9.1, you can download payloads automatically by using RDU as opposed to downloading an ISO image and mounting it for RDU workflow. For more information, see Download Updates from the Broadcom Online Repository. vCenter Quick Patch: With VCF 9.1, you can use the vCenter quick patches to upgrade vCenter with zero to 5 minutes of downtime. Quick patches carry security or critical bug fixes and cannot be used for major upgrades. Based on the services included in the patch payload, three groups of services are determined: zero, zero to 3 minutes, and 3 to 5 minutes of downtime. For more information, see the section vCenter Quick Patches. vSphere Lifecycle Manager Configure Global Remediation Settings for Clusters with vSphere Configuration Profiles Enabled: With VCF 9.1, you can configure how ESX hosts and VMs behave before and during the remediation of a cluster that you manage with an image and has vSphere Configuration Profiles enabled. For more information, see Configure the Global Remediation Settings for Clusters That Have vSphere Configuration Profiles Enabled. Integrity Verification of Customized and Exported ESX Images: VCF 9.1 introduces validation of image integrity for customized ESX images. Large enterprises often customize ESX images that require a review and sign off by internal compliance teams before use. Such validation ensures that the image has not been modified and that administrators are consistently using the compliance-approved image. For more information, see Verifying Image Integrity with SHA-256. Skip Reserved VIBs During Remediation: Starting with VCF 9.1, vSphere Lifecycle Manager improves remediation efficiency by skipping the transfer of reserved VIBs that are not part of customized ESX images, saving bandwidth and reducing task duration. vSphere Client Memory Tiering Improvements: With vCenter 9.1, the vSphere Client adds the following improvements for Memory Tiering: • Memory pane: • Shows tier 1 stats at host and cluster level in a summary page with a memory card. • Streamlines the configuration at cluster level into a single flow that includes device selection. • Enhances monitoring by plotting graphs with tiering-specific metrics. • Cluster workflows: • Memory Tiering cluster configuration allows for device selection and selection of Memory Tiering parameters. Improved Interface for GPU Passthrough Devices: With vCenter 9.1, the vSphere Client adds enumeration in human-readable form for GPU passthrough devices, simpler names in English, and filtering capabilities to enumerate the passthrough device list. VPC Transit Gateway, Traceflow, and Live Traffic Analysis available from the vSphere Client: With vCenter 9.1, you can configure an external connection for a Transit Gateway, use Traceflow to inspect the path of a packet, and get insight about tracing live traffic and bi-directional packet tracing by using Live Traffic Analysis (LTA) from the vSphere Client. To provide complete VPC configuration capabilities, vCenter 9.1 adds: • integration with external connections, which can define VPC connectivity policy. The Transit Gateway can connect to a single centralized external connection or multiple distributed external connections. • port mirroring (SPAN), which allows you to set up the range of inventory objects covered by the VPC network under the same Transit Gateway. • Virtual Network Appliance Clusters (VNAC), which enable VPC connectivity services. • IP management capabilities for IP allocation and DHCP setup. vSphere Client Usability Improvements: • VM tagging: When you create, clone or deploy a VM from a template, you can assign tags to the VM as part of the workflow. Adding tags is a separate step in the Create VM wizard. • Virtual scrolling: You can virtually scroll the grids of all managed objects, which prevents switching between pages to browse object lists with large number of entities. • Automatically adjustable columns in object lists: The column width for long strings in object lists automatically adjusts to avoid text wrapping on multiple rows. You can switch to automatic adjustment and other options by using the settings menu at the top of the Inventory tree section. • CSV export of vCenter roles and permissions: From the vSphere Client, you can export vCenter roles and permissions as a CSV file. The option is available for the global permission list and for the permission lists on inventory objects level such as vCenter instance, cluster, and ESX host. • Alphabetic order of all roles and permissions lists, including configuration views. • Automatic propagation of user permissions: User permissions set for a particular inventory object are automatically propagated to the object children by default. • Alphabetic order of object selection views: In the OVF deployment wizard, objects are sorted alphabetically to simplify configuration. • 900 rows limit per page: In the consoles for tasks and events, you can increase the row limit to 900 from the default of 300. • Live refresh of the list of events. Event Tracking: VCF 9.1 adds an Event Tracking page in the vSphere Client, which visualizes the full sequence of events when an ESX host fails and HA initiates recovery actions. The page provides a clear timeline that correlates ESX host failures, failover decisions, restarts, and recovery steps, all in one console. For more information, see Monitor and Analyze High Availability Events. vCenter Common objects identifiers between NSX and vCenter: Starting with VCF 9.1, the maximum length of the Folder object name is increased from 80 tо 255 chars for compatibility with NSX network management to enable common object identifiers between NSX and vCenter. In previous releases, NSX folder names could be too long for vCenter. For more information, see Folders in the Hierarchy. Enhanced scalability in extra-large environments: VCF 9.1 allows for up to 20% faster vCenter operations per minute. As a result, management tasks on virtual machines and ESX hosts, such as power on/off, run significantly faster. Content Library Convert Subscribed Content Library to Published Local Library: With VCF 9.1, to avoid loss of content in case the original published local library is not available, you can convert a subscribed content library to a published local content library. For example, when you decommission a vCenter instance that hosts a published library serving subscribed libraries, the capability allows a subscribed library on another vCenter instance to convert to a published library, becoming the new content distributor and maintaining content availability. Storage VAAI-NAS support for Unmap with NFS v4.1: VCF 9.1 supports space reclamation for VMs running on thin-provisioned NFS v4.1 datastores with VAAI-NAS Unmap. For more information, see vSphere Hardware Acceleration on NAS Devices. Increased Host Scale for NFS Datastores: VCF 9.1 supports up to 256 hosts per NFS v3 or NFS v4.1 datastore. This enhancement improves storage flexibility and allows for larger cluster configurations. For more information, see VMware Configuration Maximums. Partner-supported NVMe stretch cluster solutions: VCF 9.1 introduces NVMe dispersed namespaces which enable storage partners to validate and support NVMe-based stretch cluster solutions. For more information, see Requirements for VMware NVMe Storage. iSCSI support for the iSNS service: VCF 9.1 introduces automated discovery, configuration and management of iSCSI connections with the Internet Storage Name Service (iSNS) service. For more information, see Using iSNS with ESX iSCSI. vSphere High Availability Enhanced Failover Alarms: VCF 9.1 introduces fully reworked logic for vSphere High Availability failover alarm that ensures accurate, stable, and reliable failover notifications. In previous releases, HA failover alarms might intermittently toggle on or off, leading to misleading signals about cluster health. API vCenter Support for OAuth 2.0 API Tokens: With VCF 9.1, vCenter supports OAuth 2.0 API tokens, which help you manage API clients and emergency access clients to support secure automation. For more information, see Managing API Clients and Tokens. Tech Preview of FIPS API: VCF 9.1 launches a tech preview of an API that allows you to retrieve information about the FIPS cryptographic modules used by each VCF component, including version number, CMVP certificate, and CAVP certificate. For more information, see Using the FIPS API to Query FIPS Status of Components. Query API for Efficient Data Access: VCF 9.1 adds a new Query API as extension of the already existing Search Index API that delivers a fast, flexible, and scalable way to retrieve vSphere inventory data such as virtual machines and clusters. The Query API enables: • Server-side filtering based on user-defined criteria • Efficient data access with pagination, property selection, and projections • Lightweight, stateless queries without server-side state or client-side caching • Entity counts and filtered results without retrieving full datasets Designed for high-frequency automation use cases, the Query API simplifies data access. Single, unified API endpoint for managing all vCenter instances in a vCenter group: VCF 9.1 adds the vCenter group federated API (VGFA), a single, unified API endpoint for managing all vCenter instances in a vCenter group. VGFA allows you to view and manage inventory across multiple vCenter instances as if they were one, without changing any of the existing API integrations. VGFA becomes available with the configuration of VCF SSO in VCF Operations. After activation, you gain seamless access to a consolidated inventory and operations experience, consistent with the grouping capability under VCF Operations. Utilization API: VCF 9.1 adds Utilization API, which monitors vCenter capacity and usage metrics, including: • The number of active connections compared to the maximum allowed connection limit. • The endpoints through which these connections are established. • The number of requests sent to vCenter services relative to the maximum request capacity supported by those services. Building on this API, new alarms are available in the vSphere Client. These alarms are triggered when: • Active connections exceed a configured threshold, and/or • Service request volume surpasses the defined limit. You can configure threshold values by using Advanced Settings. Snapshots Enhanced snapshot operational efficiency and reliability: VCF 9.1 adds the following enhancements to snapshot operations: • Resumable Consolidation: You can resume snapshot consolidation for powered-on VMs, eliminating the need to restart the process from scratch if canceled. For more information, see Consolidate Snapshots. • Disk Chain Integrity: New safeguards detect disk chain mismatches. In the vSphere Client, you see respective alerts. The new safeguards block unsafe VM operations to prevent potential data corruption, while providing guided self-service steps to resolve the issue. • Capacity Planning Visibility: With VCF 9.1, infrastructure admins can track the Max Data to Consolidate metric for better planning and resource estimation for snapshot consolidation tasks. The metric is available in the Snapshots tile under the VCF Operations diagnostics and in the VM RuntimeInfo file, under the parameter consolidateWorkTotal. For more information, see Virtual Machine Snapshots Health inVCF Operations Health and Diagnostics. Metrics vMotion Downtime Estimates with Enhanced DirectPath: In vCenter 9.1, configuring a workload with an Enhanced DirectPath device provides you with increased visibility into the estimated downtime for a vSphere vMotion operation, enabling better workload planning and management. GPU Power Metrics for Virtual Machines: With vCenter 9.1, the Advanced Performance charts include Power Capacity Usage - GPU metrics for real-time insights into GPU power consumption at the workload level for virtual machines using NVIDIA GPUs. Distributed Resource Scheduler Intel QAT Offload for Encrypted vSphere vMotion Operations: • CPU Efficiency: QAT offloads the majority of encryption cycles, reducing Source CPU utilization by nearly 67% and reducing Destination CPU utilization by nearly 22%. • Predictability: With QAT, you see significantly lower variance in 'Total Migration Time' and 'Oracle Performance during vMotion' metrics as compared to the software-based encrypted vSphere vMotion that is sensitive to the microarchitectural interference, including cache pollution, memory bandwidth contention, and scheduler jitter. • Workload Performance: The reduction in microarchitectural interference due to QAT offload correlates to an 14% increase in Oracle transaction throughput during the migration window. vSphere Distributed Resource Scheduler (DRS) Enhancements: • Optimized DRS VM selection logic to remediate CPU and memory contention faster, prioritizing the migration of high-impact VMs and bucketing VMs to ensure that migrations directly address the most constrained resources rather than defaulting to random, low-impact moves. • Non-disruptive maintenance mode, which ensures that no workload disruptions occur during the host evacuation process. Instead, DRS notifies you why a VM cannot be evacuated when a forceful evacuation can result in performance degradation. • Streaming vMotion Orchestrator: • Streaming vMotion Execution: Removes the requirement to wait for an entire batch of migrations to complete before starting the next to ensure that the migration pipeline remains at peak saturation, preventing a single slow migration from stalling the overall progress. • Adaptive Host-Pair Distribution (Progressive Pair-Sum): To prevent resource contention on key ESX hosts, a new adaptive algorithm prioritizes the selection of distinct source and destination host pairs. By intelligently spreading the migration load across all participating hosts in the cluster before loading any single host a second time, the scheduler ensures balanced network and CPU utilization, reducing the risk of delays and NIC saturation. • Dynamic Concurrency Control: You can move beyond the static cluster-wide limit of eight concurrent migrations. You can use new advanced configuration options to fine-tune vSphere vMotion concurrency based on specific hardware capabilities such as 25/100GbE networks and cluster size, enabling the system to scale throughput linearly with the number of available hosts.
Original source - Nov 19, 2026
- Date parsed from source:Nov 19, 2026
- First seen by Releasebot:Nov 25, 2026
VMware vCenter Server by Broadcom
VMware vCenter 9.1.1.0200 Release Notes
VMware vCenter Server releases version 9.1.1.0200, a patch that resolves the CVE-2026-123890 security vulnerability. The update is available through the Broadcom Support Portal, with separate patching guidance for VCF and VMware vSphere Foundation environments.
Introduction VMware vCenter 9.1.1.0200 | 19 NOV 2026| Build 25901347 Check for additions and updates to these release notes. What's New This release resolves CVE-2026-123890. For more information on this vulnerability and its impact on Broadcom products, see VMSA-2026-0009. Upgrade Notes For supported upgrade paths from vCenter 9.1.1.0200 to later releases, see the vCenter upgrade path matrix. Build Details VMware vCenter 9.1.1.0200 Download Filename: VMware-vCenter-Server-Appliance-9.1.1.0200.25901347-patch-FP.iso Build: 25901347 Download Size: 8074.5 MB SHA256 checksum: 02eb19a2d6f9eef496012d9c2ab0464d6794d7d18c3aff57c246bcf234fccebd CVEs: CVE-2026-123890 Applying the Patch Log in to the Broadcom Support Portal to download this patch, depending on your entitlement. For download instructions, see Download Broadcom products and software. For more information on using the vCenter shells, see Broadcom knowledge base article 2100508. For VCF environments, you apply this patch by using VCF Operations. See Upgrade or Patch an Individual VCF Component. For VMware vSphere Foundation environments, see Upgrading the vCenter Appliance.
Original source All of your release notes in one feed
Join Releasebot and get updates from Broadcom and hundreds of other software products.
- Nov 19, 2026
- Date parsed from source:Nov 19, 2026
- First seen by Releasebot:Nov 25, 2026
VMware vCenter Server by Broadcom
VMware vCenter 9.0.2.0200 Release Notes
VMware vCenter Server releases version 9.0.2.0200, a patch that resolves CVE-2026-123890. The update is available through the Broadcom Support Portal, with deployment guidance for VCF and vSphere Foundation environments.
Introduction VMware vCenter 9.0.2.0200 | 19 NOV 2026 | Build 25901331 Check for additions and updates to these release notes. What's New This release resolves CVE-2026-123890. For more information on this vulnerability and its impact on Broadcom products, see VMSA-2026-0009. Upgrade Notes For supported upgrade paths from vCenter 9.0.2.0200 to later releases, see the vCenter upgrade path matrix. Build Details VMware vCenter 9.0.2.0100 Build Details Download Filename: VMware-vCenter-Server-Appliance-9.0.2.0200.25901331-patch-FP.iso Build: 25901331 Download Size: 9167.6 MB SHA256 checksum: 72c33220447b0533f3efa083c80532a33f15e090b275f4a248c8713bf3f5154e CVEs CVE-2026-123890 Applying the Patch Log in to the Broadcom Support Portal to download this patch, depending on your entitlement. For download instructions, see Download Broadcom products and software. For more information on using the vCenter shells, see Broadcom knowledge base article 2100508. For VCF environments, you apply this patch by using VCF Operations. See Upgrade or Patch an Individual VCF Component. For VMware vSphere Foundation environments, see Upgrading the vCenter Appliance.
Original source - Nov 19, 2026
- Date parsed from source:Nov 19, 2026
- First seen by Releasebot:Nov 25, 2026
VMware vCenter Server by Broadcom
VMware vCenter 8.0 Update 3m
VMware vCenter Server releases 8.0 Update 3m with a security fix, new alerts for Secure Boot certificate issues and API session limits, and fixes for backup, lifecycle management, content library, and vSphere Client problems.
Introduction VMware vCenter 8.0 Update 3m | 19 NOV 2026 | ISO Build 25934264 Check for additions and updates to these release notes. What's New This release resolves CVE-2026-123890. For more information on this vulnerability and its impact on Broadcom products, see VMSA-2026-0009. TZData: vCenter has upgraded open-source packages to incorporate the latest timezone changes. eMudhra: vCenter has upgraded open-source packages to confirm that eMudhra certificates are no longer in use. For Photon OS updates, see VMware vCenter Server Appliance Photon OS Security Patches. Secure Boot Platform Key (PK) Remediation: To address Microsoft 2011 Secure Boot certificate expirations, as detailed in Broadcom knowledge base article 423893, vCenter 8.0 Update 3m introduces a vCenter alarm to proactively warns administrators when Secure Boot-enabled, powered-on virtual machines have an out-of-date NULL PK. This per-VM alarm is triggered once vCenter and the ESX host are upgraded to 8.0 Update 3m. vCenter alert on API session limits: vCenter 8.0 Update 3m adds an alert to the vCenter Appliance Management Interface (VAMI) that notifies you when vCenter API sessions reach a preconfigured threshold and prevents vCenter management capabilities such as API endpoints and vSphere Client to become unresponsive. Previously, the health alerts in vCenter did not include the API session metric and you could see a Healthy status despite the API session limit exhaustion. Now, you see the vCenter Session Health metric and can take action accordingly. The metric is configurable, with a default value of 90%. Upgrade Notes For supported upgrade paths from vCenter 8.0 Update 3m to later releases, see the vCenter upgrade path matrix. Build Details VMware vCenter 8.0 Update 3m Download Filename: VMware-vCenter-Server-Appliance-8.0.3.01200-25934264-patch-FP.iso Build: 25934264 Download Size: 8470 MB sha256checksum: 0666cff51ee265616022f1bb99f8b9c495caf626dfe2602cf7ddb8a33e7c8c0c CVEs: CVE-2026-123890 Download and Installation Log in to the Broadcom Support Portal to download this patch. See these KBs for details on the authenticated online and offline download: 390121, 390098, and 389276. For more information on using the vCenter Server shells, see VMware knowledge base article 2100508. For more information on patching vCenter Server, see Patching and Updating vCenter Server 8.0 Deployments. For more information on staging patches, see Upgrading the vCenter Server Appliance. Resolved Issues Miscellaneous Issues After renewal, you see Solution User certificates with 2-year validity instead of the expected 10 years When you use the vSphere Certificate Manager Utility to renew or replace a solution user certificate, if you set the option Do you wish to generate all certificates using configuration file to Y, the new certificates default to a 2-year validity period. If the option is set to N, the solution user certificates are generated with a validity period of 10 years, which is the expected and documented behavior. This issue is resolved in this release. vSphere Client and vCenter Issues After a vCenter upgrade, the SNMP agent is enabled by default After a vCenter upgrade, the SNMP agent might be automatically enabled, even if it was not active before the upgrade. This issue is resolved in this release. Compliance checks or remediation against a vSphere Lifecycle Manager desired image might fail due to excessive metadata During scans, remediations, or updates, vCenter sends excessive metadata to ESX hosts while processing depots that contain base images, add-ons, components, and manifests. As a result, such metadata might overload the memory pool of an ESX host and lead to scan and remediation failures. In the vSphere Client, you might see errors such as: Host status is unknown An internal error occurred while staging/remediating host SHA-1 signature found in host certificate False. Support for certificates with weak signature algorithm SHA-1 has been removed in ESXi 8.0. To proceed with upgrade, replace it with a SHA-2 signature based certificate. The ESXi host encounters memory exhaustion within the host/vim/vmvisor/settingsd-task-forks resource group, as described in Broadcom knowledge base article 449182. The default memory limit is insufficient for the vSphere Lifecycle Manager daemon to parse the metadata zip files provided by the vCenter Server during the upgrade/remediation process. The /var/run/log/lifecycle.log file on the ESXi host, you see an error such as Current ESXi version does not provide a mechanism to mount a tardisk into a ramdisk. This issue is resolved in this release. Scheduled vCenter file-based backups might fail intermittently when several vCenter instances back up to the same backup location Before each backup, vCenter checks the backup server, creates a directory vCenter/backup_<YYYYMMDD-HHMM> in the backup location, writes a sample file to it, and deletes every vCenter/backup_* directory. The vCenter/backup_<YYYYMMDD-HHMM> directory has only a one-minute UTC timestamp and since backup checks of different vCenter instances might overlap, the creation and deletion of backup directories for the different vCenter instances might be misplaced. As a result, you might see backup failures before any data is transferred. For example: SFTP: /var/log/vmware/applmgmt/applmgmt.log shows curl: (21) mkdir command failed for vCenter/backup_<timestamp>/, and the job fails with "Backup job failed to start due to server validation failure. NFS: /var/log/vmware/applmgmt/backupValidate.log shows Failed in backup connection validation: Failed to dispatch sample file, and applmgmt.log shows data stream command status: errcode: 2. This issue is resolved in this release. With the fix, each vCenter instance names its directory with the pattern backup_<hostname>_<YYYYMMDD-HHMM> and deletes only that directory. Content library synchronization occasionally fails due to a reported missing file, even though the library is fully in sync and the file exists on the publisher The pagination queries during a content library sync might not use a fully deterministic sort order. As a result, for libraries containing more than 100 items, some file records belonging to the same item might be returned in an inconsistent order across paginated queries. Occasionally, a file that is already present, might be identified as missing and scheduled for deletion during a subscribed library sync. This issue is resolved in this release. The pagination queries used during library-item sync now sort deterministically by item, version, and file identifiers, ensuring files are consistently accounted for across paginated results. You see an in-progress alarm for vSphere High Availability (HA) failover for powered-off or deleted virtual machines Due to an internal race condition in the Fault Domain Manager (FDM), a VM might incorrectly remain protected in the memory of the FDM primary host. As a result, in the vSphere Client, you see an in-progress alarm for vSphere HA failover for powered-off or deleted virtual machines. This issue is resolved in this release. vCenter might become unresponsive due to a sync issue with the internal database During configuration changes of a distributed virtual portgroup, vCenter might lose sync with the internal database. As a result, when the sync is reestablished, the vpxd service might fail instead of recovering gracefully, and vCenter becomes unresponsive. This issue is resolved in this release. vCenter vpxd service might intermittently fail during backup operations due to a missing InstanceUUID in a virtual machine A missing InstanceUUID parameter in a virtual machine during VM backup operations with a 3-rd party tool might cause the vpxd service to fail with a core.vpxd-worker dump and Program terminated with signal SIGABRT, Aborted error. This issue is resolved in this release. After an upgrade, ESXi hosts might lose access to vSphere Virtual Volumes datastore if the VASA Provider is version 4.0 or earlier After upgrading an ESXi host, it might lose access to the vSphere Virtual Volumes datastore and the VASA Provider shows a sync error, indicating broken communication between the vvold service and the VASA Provider. The issue occurs with VASA 4.0 or earlier, when the retainVasaProviderCertificate flag is set to True and a self-signed certificate is used, because the certificate is not stored in PEM format. This issue is resolved in this release. VM web console shows a black screen when the guest OS enters power-saving mode When a virtual machine guest operating system enters power-saving mode after a period of inactivity, the guest OS terminates all active web console sessions. If you attempt to open a new web console in the vSphere Client, a black screen appears with a loading spinner that spins indefinitely. This issue is resolved in this release. Advanced export omits Type and User columns from exported CSV files When you use Advanced export in the vSphere Client, the resulting CSV file omits the Type and User columns, regardless if you select All columns or Selected columns in the export options. This issue is resolved in this release. Upgrade Issues vCenter file-based backups to an OpenSSH 9.9 SFTP server with PerSourcePenalties enabled might fail with: curl: (2) Failure establishing ssh session: -43, Failed getting banner During the creation of a SSH tunnel, vCenter performs host-key discovery and authentication checks before transferring the backup. This connection sequence can trigger OpenSSH 9.9 per-source penalties, temporarily blocking connections from vCenter and preventing the password-authenticated SFTP fallback from completing the SSH handshake. This issue is resolved in this release. The fix adjusts the connection sequence and reduces authentication attempts to allow backup transfers to proceed. vSAN Issues Configuring vSAN File Service with Active Directory domain fails with an error for exception caught when running pre-flight check on the file server In the vSphere Client, when you create a file service domain with AD and click Next, you see an error such as: Failed to check domain configuration: Exception caught when running preflight check on file server. The issue occurs because querying the Active Directory domain for LDAP SRV records returns multiple duplicate entries for the same Domain Controller hostname. As a result, the pre-flight check script causes an exception and fails the file service enablement workflow. vSphere Lifecycle Manager Issues VMware vSphere Update Manager Download Service (UMDS) configuration removes deprecated hostupdate URLs and adds entitlement token support Starting with vCenter 8.0 Update 3m, UMDS configuration no longer includes the deprecated hostupdate URLs such as https://hostupdate.vmware.com/software/VUM/PRODUCTION/main/vmw-depot-index.xml. The new depots are located at https://dl.broadcom.com and require an entitlement token to access the content. You can use the new CLI option vmware-umds -S --add-entitlement-token <tokenID> to configure UMDS with the new depot URLs using your entitlement token. This issue is resolved in this release. For more information, see Broadcom knowledge base article 390123. Known Issues from Previous Releases Installation, Upgrade, and Migration Issues If you do not open port 9087 in your firewall between ESXi hosts and vCenter, compliance checks and vSphere HA might fail after vCenter update to 8.0 Update 3 Starting from 8.0 Update 3, the vSphere Lifecycle Manager downloads updates for ESXi hosts by a HTTPS connection to the vCenter instance on port 9087. If you do not open port 9087 in your firewall between ESXi hosts and vCenter, you might see compliance check errors. For example, in the lifecycle.log you see messages such as: <Timestamp> In(14) lifecycle[2112988]: Downloader:373 Opening https://<VC-FQDN>:9087/vum/repository/hostupdate/__micro-depot__vendor-DEL__DEL-ESXi-8.0-Addon-cumulative_metadata__index__.xml for download <Timestamp> Wa(12) lifecycle[2112988]: Downloader:210 Download failed: <urlopen error timed out>, 9 retry left... In addition, vSphere HA might fail to start. Workaround: Open port 9087 in your firewall between ESXi hosts and vCenter by using the TCP protocol. In a mixed vSphere 7.x and 8.x environment with vSphere DRS, an incompatible virtual machine might prevent an ESXi host to enter maintenance mode In a mixed vSphere 7.x and 8.x environment with DRS, a VM of 7.x version that is not compatible with ESXi 8.0 Update 1 and later might prevent an ESXi 8.0 Update 1 host to enter maintenance mode. The issue is specific for virtual machines with VMDK on a vSphere Virtual Volumes datastore. In the vSphere Client, you see an error such as Waiting for all VMs to be powered off or suspended or migrated. In a DRS cluster check the Faults page on the DRS tab for troubleshooting. Workaround: Power-off the incompatible virtual machine. vSphere Lifecycle Manager baseline check compliance fails on ESXi hosts of version 7.0 GA in a vCenter 8.0 Update 3 system Due to a limitation of the esxupdate memory resource pool on 7.0 GA ESXi hosts, a vSphere Lifecycle Manager baseline check compliance scan might fail on 7.0 GA ESXi host in a vCenter 8.0 Update 3 system with error such as The host returns esxupdate error codes: -1. The host esxupdate.log contains an error such as: <Timestamp> esxupdate: <PID>: esxupdate: ERROR: vmware.runcommand.RunCommandError: Error running command '['/sbin/smbiosDump']': [Errno 12] Cannot allocate memory. The vmkernel.log contains error such as: <Timestamp> cpu0:<PID>)Admission failure in path: host/vim/vmvisor/esxupdate/python.<PID>:python.<PID>:uw.<PID>. This issue is specific for 7.0 GA ESXi hosts, as esxupdate memory allocation is increased in 7.0 Update 1 and later. Workaround: Use an ISO upgrade baseline to upgrade the 7.0 GA ESXi hosts to a 8.x version or revert the vCenter system back to version 7.0 and upgrade the hosts to a version of 7.0 Update 1 and later. You see an error Failed to get ceip status in the Virtual Appliance Management Interface (VAMI) during update to vCenter Server 8.0 Update 1 During an update, vCenter stops and restarts the VMDir service and within this interval, if you try to log in to the VAMI, you might see an error such as Failed to get ceip status. This is expected and does not indicate an actual issue with the vCenter system. Workaround: Wait for the VMDir service to restart and refresh the Virtual Appliance Management Interface. If you click NEXT before the progress bar reaches 100% in a vCenter Server Lifecycle Manager plug-in upgrade, the Server Lifecycle Manager service fails In the Upgrade Plug-in step of the vCenter Server Lifecycle Manager plug-in upgrade wizard, if you click NEXT before the progress bar reaches 100%, the Server Lifecycle Manager service fails. Workaround: Wait for the progress bar to reach 100% before you click NEXT. vCenter upgrade or update to 8.0 Update 2a or later fails during precheck with the error "VMCA root certificate validation failed" If your vCenter system has a legacy VMCA root certificate dating back to version 5.x which does not have the Subject Key Identifier (SKID) extension, upgrades and updates to vCenter 8.0 Update 2 and later fail because the OpenSSL version 3.0 in 8.0 Update 2 is not compatible with legacy root certificates. vCenter Server 8.0 Update 2a adds a precheck to detect this issue and shows the error message VMCA root certificate validation failed if the source vCenter has VMCA root certificate without SKID. Workaround: Regenerate a VMCA root certificate by following the steps in VMware knowledge base article 94840. You see a "vc.health.error.dbjob3" warning after a vCenter upgrade In the vSphere Client or the in Virtual Appliance Management Interface, you might see the warning vc.health.error.dbjob3 after a vCenter upgrade although the vCenter overall health status is green. This issue does not affect vCenter operations, it can only affect historical statistics when some data does not roll up for more than 72 hours. Workaround: See Delete old tasks, events and statistics data in vCenter Server 5.x, 6.x, 7.x and 8.x how to clear stats data, if not relevant anymore. Update to vCenter 8.0 Update 3 might fail with an error "Destination path '/storage/analytics/stage/...' already exists" Starting with vCenter 8.0 Update 3, the analytics service stores telemetry log files in a new directory. In rare cases, if previous update attempts had failed and reverted, when patching to vCenter 8.0 Update 3, the attempt to copy the telemetry log files to the new location might fail because these files already exist from a prior patching attempt. In the patchrunner.log file, you see an error such as Destination path '/storage/analytics/stage/XXXXXX_processed_logs' already exists. Workaround: Delete all files under /storage/log/vmware/analytics/stage, /storage/log/vmware/analytics/prod, /storage/analytics/stage, and /storage/analytics/prod, and retry the update. You see a security warning for the ESX Agent Manager configuration during the pre-check phase of a vCenter upgrade During the pre-check phase of a vCenter update or upgrade, in the vSphere Client and logs, you might see an error such as: Source ESX Agent Manager Configuration contains URLs that are not trusted by the System! Verify following URLs and their respective statuses and follow KB 93526. Workaround: For more information, see VMware knowledge base article 93526. Firmware compliance details are missing from a vSphere Lifecycle Manager image compliance report for an ESXi standalone host Firmware compliance details might be missing from a vSphere Lifecycle Manager image compliance report for an ESXi standalone host in two cases: • You run a compliance report against a standalone host managed with a vSphere Lifecycle Manager image from vSphere Client and then navigate away before the compliance report gets generated. • You trigger a page refresh after the image compliance reports are generated. In such cases, even when you have the firmware package available in the Desired State, the firmware compliance section remains empty when you revisit or refresh the vSphere Client browsing session. If you use GET image compliance API, then firmware compliance details are missing from the response. Workaround: Invoke the image compliance scan for a standalone host managed with a vSphere Lifecycle Manager image by using the vSphere Client and do not navigate away or refresh the browser. For API, use the Check image compliance API for fetching the firmware details as apposed to GET image compliance. If you apply a host profile using a software FCoE configuration to an ESXi 8.0 host, the operation fails with a validation error Starting from vSphere 7.0, software FCoE is deprecated, and in vSphere 8.0 software FCoE profiles are not supported. If you try to apply a host profile from an earlier version to an ESXi 8.0 host, for example to edit the host customization, the operation fails. In the vSphere Client, you see an error such as Host Customizations validation error. Workaround: Disable the Software FCoE Configuration subprofile in the host profile. URL-based patching or file-based backup of vCenter 8.0 Update 2 might fail due to OpenSSL noncompliance to Federal Information Processing Standards (FIPS) With vCenter 8.0 Update 2, OpenSSL works only with Diffie-Hellman parameters compliant to NIST SP 800-56A and FIPS 140-2. For URL-based patching or file-based backup of vCenter 8.0 Update 2 systems, FTPS servers in your environment must support the following ciphers: DHE-RSA-AES256-SHA | TLS_DHE_RSA_WITH_AES_256_CBC_SHA | 39 DHE-DSS-AES256-SHA | TLS_DHE_DSS_WITH_AES_256_CBC_SHA | 38 AES256-SHA | TLS_RSA_WITH_AES_256_CBC_SHA | 35 EDH-RSA-DES-CBC3-SHA | TLS_DHE_RSA_WITH_3DES_EDE_CBC_SHA | 16 EDH-DSS-DES-CBC3-SHA | TLS_DHE_DSS_WITH_3DES_EDE_CBC_SHA | 13 DES-CBC3-SHA | TLS_RSA_WITH_3DES_EDE_CBC_SHA | 0A DHE-RSA-AES128-SHA | TLS_DHE_RSA_WITH_AES_128_CBC_SHA | 33 DHE-DSS-AES128-SHA | TLS_DHE_DSS_WITH_AES_128_CBC_SHA | 32 AES128-SHA | TLS_RSA_WITH_AES_128_CBC_SHA | 2F Workaround: Make sure your file servers are FIPS compliant. VMNICs might be down after an upgrade to ESXi 8.0 If the peer physical switch of a VMNIC does not support Media Auto Detect, or Media Auto Detect is disabled, and the VMNIC link is set down and then up, the link remains down after upgrade to or installation of ESXi 8.0. Workaround: Use either of these 2 options: • Enable the option media-auto-detect in the BIOS settings by navigating to System Setup Main Menu, usually by pressing F2 or opening a virtual console, and then Device Settings > <specific broadcom NIC> > Device Configuration Menu > Media Auto Detect. Reboot the host. • Alternatively, use an ESXCLI command similar to: esxcli network nic set -S <your speed> -D full -n <your nic>. With this option, you also set a fixed speed to the link, and it does not require a reboot. After upgrade to ESXi 8.0, you might lose some nmlx5_core driver module settings due to obsolete parameters Some module parameters for the nmlx5_core driver, such as device_rss, drss, and rss, are deprecated in ESXi 8.0 and any custom values, different from the default values, are not kept after an upgrade to ESXi 8.0. Workaround: Replace the values of the device_rss, drss and rss parameters as follows: • device_rss: Use the DRSS parameter. • drss: Use the DRSS parameter. • rss: Use the RSS parameter. Miscellaneous Issues In a vCenter Server system with DPUs, if IPv6 is disabled, you cannot manage DPUs Although the vSphere Client allows the operation, if you disable IPv6 on an ESXi host with DPUs, you cannot use the DPUs, because the internal communication between the host and the devices depends on IPv6. The issue affects only ESXi hosts with DPUs. Workaround: Make sure IPv6 is enabled on ESXi hosts with DPUs. You might see 10 min delay in rebooting an ESXi host on HPE server with pre-installed Pensando DPU In rare cases, HPE servers with pre-installed Pensando DPU might take more than 10 minutes to reboot in case of a failure of the DPU. As a result, ESXi hosts might fail with a purple diagnostic screen and the default wait time is 10 minutes. Workaround: None. If you have an USB interface enabled in a remote management application that you use to install ESXi 8.0, you see an additional standard switch vSwitchBMC with uplink vusb0 Starting with vSphere 8.0, in both Integrated Dell Remote Access Controller (iDRAC) and HP Integrated Lights Out (ILO), when you have an USB interface enabled, vUSB or vNIC respectively, an additional standard switch vSwitchBMC with uplink vusb0 gets created on the ESXi host. This is expected, in view of the introduction of data processing units (DPUs) on some servers but might cause the VMware Cloud Foundation Bring-Up process to fail. Workaround: Before vSphere 8.0 installation, disable the USB interface in the remote management application that you use by following vendor documentation. After vSphere 8.0 installation, use the ESXCLI command esxcfg-advcfg -s 0 /Net/BMCNetworkEnable to prevent the creation of a virtual switch vSwitchBMC and associated portgroups on the next reboot of host. See this script as an example: ~# esxcfg-advcfg -s 0 /Net/BMCNetworkEnable The value of BMCNetworkEnable is 0 and the service is disabled. ~# reboot On host reboot, no virtual switch, PortGroup and VMKNIC are created in the host related to remote management application network. If an NVIDIA BlueField DPU is in hardware offload mode disabled, virtual machines with configured SR-IOV virtual function cannot power on NVIDIA BlueField DPUs must be in hardware offload mode enabled to allow virtual machines with configured SR-IOV virtual function to power on and operate. Workaround: Always use the default hardware offload mode enabled for NVIDIA BlueField DPUs when you have VMs with configured SR-IOV virtual function connected to a virtual switch. ESXi hosts might become unresponsive, and you see a vpxa dump file due to a rare condition of insufficient file descriptors for the request queue on vpxa In rare cases, when requests to the vpxa service take long, for example waiting for access to a slow datastore, the request queue on vpxa might exceed the limit of file descriptors. As a result, ESXi hosts might briefly become unresponsive, and you see a vpxa-zdump.00* file in the /var/core directory. The vpxa logs contain the line Too many open files. Workaround: None. The vpxa service automatically restarts and corrects the issue. Networking Issues Overlapping hot-add and hot-remove operations for DirectPath I/O devices might fail With vSphere 8.0 Update 1, by using vSphere API you can add or remove a DirectPath I/O device without powering off VMs. However, if you run several operations at the same time, some of the overlapping tasks might fail. Workaround: Plan for 20 seconds processing time between each hot-add or hot-remove operation for DirectPath I/O devices. Hot adding and removing of DirectPath I/O devices is not automatically enabled on virtual machines With vSphere 8.0 Update 1, by using vSphere API you can add or remove a DirectPath I/O device without powering off VMs. When you enable the hotplug functionality that allows you to hot add and remove DirectPath I/O devices to a VM, if you use such a VM to create an OVF and deploy a new VM, the new VM might not have the hotplug functionality automatically enabled. Workaround: Enable the hotplug functionality as described in Hot-add and Hot-remove support for VMDirectPath I/O Devices. You cannot set the Maximum Transmission Unit (MTU) on a VMware vSphere Distributed Switch to a value larger than 9174 on a Pensando DPU If you have the vSphere Distributed Services Engine feature with a Pensando DPU enabled on your ESXi 8.0 system, you cannot set the Maximum Transmission Unit (MTU) on a vSphere Distributed Switch to a value larger than 9174. Workaround: None. You see link flapping on NICs that use the ntg3 driver of version 4.1.3 and later When two NICs that use the ntg3 driver of versions 4.1.3 and later are connected directly, not to a physical switch port, link flapping might occur. The issue does not occur on ntg3 drivers of versions earlier than 4.1.3 or the tg3 driver. This issue is not related to the occasional Energy Efficient Ethernet (EEE) link flapping on such NICs. The fix for the EEE issue is to use a ntg3 driver of version 4.1.7 or later, or disable EEE on physical switch ports. Workaround: Upgrade the ntg3 driver to version 4.1.8 and set the new module parameter noPhyStateSet to 1. The noPhyStateSet parameter defaults to 0 and is not required in most environments, except they face the issue. You cannot use Mellanox ConnectX-5, ConnectX-6 cards Model 1 Level 2 and Model 2 for Enhanced Network Stack (ENS) mode in vSphere 8.0 Due to hardware limitations, Model 1 Level 2, and Model 2 for Enhanced Network Stack (ENS) mode in vSphere 8.0 is not supported in ConnectX-5 and ConnectX-6 adapter cards. Workaround: Use Mellanox ConnectX-6 Lx and ConnectX-6 Dx or later cards that support ENS Model 1 Level 2, and Model 2A. Pensando DPUs do not support Link Layer Discovery Protocol (LLDP) on physical switch ports of ESXi hosts When you enable LLDP on an ESXi host with a DPU, the host cannot receive LLDP packets. Workaround: None. Storage Issues vSphere Storage vMotion operations might fail in a vSAN environment due to an unauthenticated session of the Network File Copy (NFC) manager Migrations to a vSAN datastore by using vSphere Storage vMotion of virtual machines that have at least one snapshot and more than one virtual disk with different storage policy might fail. The issue occurs due to an unauthenticated session of the NFC manager because the Simple Object Access Protocol (SOAP) body exceeds the allowed size. Workaround: First migrate the VM home namespace and just one of the virtual disks. After the operation completes, perform a disk only migration of the remaining 2 disks. vCenter Server and vSphere Client Issues PR 3667115: When editing vSphere Namespace CPU limits in the vSphere Client, values higher than 1000 GHz are incorrectly handled If you set a CPU limit on a vSphere Namespace higher than 1000 GHz, the vSphere Client might fall back to the default unit (MHz) instead of the respective unit in Terahertz (THz). For example, if you set a CPU limit of 1500 GHz, you should see the metric as 1.5 THz, but in the Resource Limits modal, you see a value of 1.5 with the unit selection box appearing empty or unselected. If you save the setting in this state, the system defaults to MHz, effectively slashing the 1500 GHz (1.5 THz) limit down to just 1.5 MHz. This issue is resolved in this release. You cannot hide or show plug-ins with 5-part version numbers in the vSphere Client In the vSphere Client, you cannot hide or show plug-ins registered with a 5-part version number, such as 9.0.0.0.12345, due to an issue with the serialization of 5-part package versions. Workaround: None. Instead of hiding or showing a plug-in with a 5-part version number in the vSphere Client, you can unregister and re-register the plug-in to achieve a similar result. PR 3667116: In the vSphere Client, very large SCSI vSphere Virtual Volumes datastores might display incorrect capacity and free space values When a SCSI vSphere Virtual Volumes datastore exceeds several exabytes, the vSphere Client fails to format the numerical value because it exceeds the maximum unit type defined in the formatting service. As a result, you see such capacity values as undefined. For example, 8 undefined free or 8 undefined capacity. The CLI and the Managed Object Browser (MOB) report the correct values. This issue is resolved in this release. The fix updates the storage unit service of the vSphere Client to handle and scale correctly extremely large capacity values to the maximum supported units. You cannot upload logs packages to a VMware service request by using the vSphere Client You cannot upload logs packages to a VMware service request by navigating in the vSphere Client to Administration > Support > Upload File to Service Request. Instead, you see a link to a KB article that provides steps to upload log bundles in the Broadcom Support Portal. This is expected. Workaround: Follow the steps in Uploading files to cases on the Broadcom Support Portal. A rare race in the vCenter automated space_cleanup utility when file-based backup is configured with an NFS volume might cause high memory usage vCenter 8.0 Update 3h has an automated space cleanup utility which is scheduled to run everyday at midnight to clean up old logs. In rare situations, due to a race condition, this scheduled cleanup task might conflict with the file-based backup and restore configured with an NFS mount point. As a result, you see high memory utilization from the space_utility process, which might consume most memory on the vCenter. Instance. Workaround: See KB 422390. When you move a standalone ESXi host back to a cluster that you manage with vSphere Lifecycle Manager images, you might see an error in the vSphere Client If you move out an ESXi host from a cluster that you manage with vSphere Lifecycle Manager images, it becomes a standalone host that is connected to a vCenter Server instance but is not part of any cluster. If you move such a host back to a cluster, in the Updates tab of the vSphere Client you might see an error such as The host [IP] is not a vLCM managed standalone host. This message does not indicate a functional issue. Workaround: Refresh the vSphere Client session or change the tab and return to the Updates tab. You see the same license product name displayed multiple times in the vSphere Client Starting with vSphere 8.0 Update 2b, you can apply a single Solution License to the components of VMware vSphere Foundation and VMware Cloud Foundation. In different screens in the vSphere Client, you might see the license product name multiplied by the number of components for which you use the license. For example, if you use a vSphere 8 Enterprise Plus for VMware Cloud Foundation license for 3 components, such as ESXi, vCenter, and vSphere with Tanzu, you see the name listed 3 times. Workaround: None An external gateway firewall might block vSphere Pod traffic to clusterIPs When you deploy Supervisor Services on vSphere Pods with Supervisors configured with the VDS stack, traffic from the vSphere Pod to ClusterIPs goes through the external gateway and a custom firewall can block it. Workaround: For more information, see vSphere Pod Traffic to ClusterIP Time-outs. A scheduled task fails and doesn't schedule further runs With vSphere 8.0 Update 2, if a vCenter user is unauthorized or unauthenticated, all scheduled tasks they own fail and cannot be scheduled until the user privileges are restored or a different vSphere user takes over the scheduled tasks. In the vSphere Client, you see messages for failed tasks and reasons for the failure. Workaround: Any vSphere user with sufficient privileges to edit scheduled tasks, including the current task owner with restored privileges, can click Edit and submit the scheduled task, without actually changing the scheduled task. For more information, see Scheduling vSphere Tasks. Virtual Machine Management Issues The vpxd agent might fail after expanding the disk size of a virtual machine with a NVMe controller in a vCenter 8.0 Update 3 mixed environment If you have ESXi hosts of version 8.0 Update 1 and earlier in your vCenter 8.0 Update 3 system, expanding the disk of a VM with a NVMe controller might cause the vpxd service to fail with core.vpxd-worker coredump. Workaround: Upgrade your ESXi hosts of version 8.0 Update 1 and earlier to 8.0 Update 3. Alternatively, use the VMware Host Client to extend the disk size from Edit settings of the VM. vSphere Lifecycle Manager Issues In the vSphere Client, you see a different count of components in a vSphere Lifecycle Manager image When you prepare a vSphere Lifecycle Manager image for a cluster or standalone ESXi host, and manually add or remove components, you might see a different count of the components in Updates > Hosts > Image > Components and in the list of components when you click Show details. The discrepancy occurs when the vSphere Lifecycle Manager considers not to use some of the additional components, for example if a driver is being deprecated, or if you remove a component, such as VMware Tools or Host Client. Workaround: None. You can safely ignore the difference in the count, because it does not impact the actual list of components that vSphere Lifecycle Manager uses for the image installation. You cannot edit the VMware vSphere Lifecycle Manager Update Download scheduled task In the vSphere Client, when you navigate to a vCenter Server instance and select Scheduled Tasks under the Configure tab, if you select the VMware vSphere Lifecycle Manager Update Download task and click Edit, you cannot modify the existing settings. Workaround: You can edit the VMware vSphere Lifecycle Manager Update Download task by following the steps in the topic Configure the vSphere Lifecycle Manager Automatic Download Task. Manually applied security advanced options on a vCenter system might not persist across vSphere Lifecycle Manager operations Some of all manually applied security advanced options on a vCenter system might not persist across vSphere Lifecycle Manager operations, such as upgrade, update, backup, or restore. Workaround: Re-apply the manual settings after the vSphere Lifecycle Manager task completes. If a parallel remediation task fails, you do not see the correct number of ESXi hosts that passed or skipped the operation With vSphere 8.0, you can enable vSphere Lifecycle Manager to remediate all hosts that are in maintenance mode in parallel instead of in sequence. However, if a parallel remediation task fails, in the vSphere Client you might not see the correct number of hosts that passed, failed, or skipped the operation, or even not see such counts at all. The issue does not affect the vSphere Lifecycle Manager functionality, but only the reporting in the vSphere Client. Workaround: None. A remediation task by using vSphere Lifecycle Manager might intermittently fail on ESXi hosts with DPUs When you start a vSphere Lifecycle Manager remediation on an ESXi hosts with DPUs, the host upgrades and reboots as expected, but after the reboot, before completing the remediation task, you might see an error such as: A general system error occurred: After host … remediation completed, compliance check reported host as 'non-compliant'. The image on the host does not match the image set for the cluster. Retry the cluster remediation operation. This is a rare issue, caused by an intermittent timeout of the post-remediation scan on the DPU. Workaround: Reboot the ESXi host and re-run the vSphere Lifecycle Manager compliance check operation, which includes the post-remediation scan. VMware Host Client Issues VMware Host Client might display incorrect descriptions for severity event states When you look in the VMware Host Client to see the descriptions of the severity event states of an ESXi host, they might differ from the descriptions you see by using Intelligent Platform Management Interface (IPMI) or Lenovo XClarity Controller (XCC). For example, in the VMware Host Client, the description of the severity event state for the PSU Sensors might be Transition to Non-critical from OK, while in the XCC and IPMI, the description is Transition to OK. Workaround: Verify the descriptions for severity event states by using the ESXCLI command esxcli hardware ipmi sdr list and Lenovo XCC. Security Features Issues If you use an RSA key size smaller than 2048 bits, RSA signature generation fails Starting from vSphere 8.0, ESXi uses the OpenSSL 3.0 FIPS provider. As part of the FIPS 186-4 requirement, the RSA key size must be at least 2048 bits for any signature generation, and signature generation with SHA1 is not supported. Workaround: Use RSA key size larger than 2048. Backup and Restore Issues SSH File Transfer Protocol (SFTP) backups fail while creating a directory on a remote backup server Repeated re-connection to a remote backup server while trying to create a SSH tunnel might cause backup server to reject connections from vCenter. As a result, in the backup logs, you see an error such as Failure establishing ssh session: -43, Failed getting banner. Workaround: See KB 399004.
Original source - Oct 12, 2026
- Date parsed from source:Oct 12, 2026
- First seen by Releasebot:Nov 25, 2026
VMware vCenter Server by Broadcom
VMware vCenter 9.1.1.0100 Release Notes
VMware vCenter Server releases version 9.1.1 with security enhancements and fixes. The notes also flag upgrade risks involving vSphere Supervisor data loss and NTP prechecks, plus an Auto Deploy certificate issue and workaround.
VMware vCenter 9.1.1.0100 | 12 OCT 2026| Build 25784172 What's New This release contains various security enhancements and delivers fixes as described in the Resolved Issues section. Build Details VMware vCenter 9.1.1.0100 Download Filename: VMware-vCenter-Server-Appliance-9.1.1.0100.25784172-patch-FP.iso Build: 25784172 Download Size: 8068.7 MB SHA256 checksum: 65b0b7b77f8f72b414584af57fd1251f6b7e34948c0f6f09c3a893ef2e9929ca Applying the Patch Log in to the Broadcom Support Portal to download this patch, depending on your entitlement. For download instructions, see Download Broadcom products and software. For more information on using the vCenter shells, see Broadcom knowledge base article 2100508. For VCF environments, you apply this patch by using VCF Operations. See Upgrade or Patch an Individual VCF Component. For VMware vSphere Foundation environments, see Upgrading the vCenter Appliance. Resolved Issues Upgrade Issues A reset of the vSphere Lifecycle Manager database might cause data loss in the vSphere Supervisor If the vSphere Lifecycle Manager database in your environment is reset before upgrading vCenter from versions 8.0 Update 3 and later or 9.0.x to 9.1.0 or 9.1.1, the upgrade might cause data loss in the vSphere Supervisor. To avoid data loss, before a vCenter upgrade, you must first check your environment and take mitigation steps. vCenter upgrade or patch to version 9.1.1 fails during the prechecks with error message: Unable to run vCenter NTP server check The NTP precheck fails on vCenter instances configured with a non-UTC time zone. Known Issues ESX hosts provisioned with Auto Deploy might not automatically join the target vCenter instance due to invalid SSL certificate In some cases, such as when VMware Certificate Authority (VMCA) is configured as a subordinate CA under an external enterprise root, the certificate file of an ESX host might contain more than one certificate. As a result, when you run an Auto Deploy rule to provision such hosts, they boot successfully, but do not automatically join the target vCenter instance. You can manually add the hosts to the vCenter instance. Workaround: To extract just the leaf certificate and replace the exising file while keeping a backup, run the following set of commands: openssl x509 -in /var/lib/rbd/ssl/host-id/rui.crt -out /tmp/rui.crt.leaf cp /var/lib/rbd/ssl/host-id/rui.crt /var/lib/rbd/ssl/host-id/rui.crt.orig.bak cp /tmp/rui.crt.leaf /var/lib/rbd/ssl/host-id/rui.crt Rerun the Auto Deploy rule to boot the ESX host on the target vCenter instance.
Original source Similar to VMware vCenter Server with recent updates:
- Sep 3, 2026
- Date parsed from source:Sep 3, 2026
- First seen by Releasebot:Nov 25, 2026
VMware vCenter Server by Broadcom
vCenter 9.1.1.0 Release Notes
VMware vCenter Server releases 9.1.1 with automated Secure Boot key remediation, VM affinity policies, and DRS and HA support for Memory Tiering. The update also strengthens backup server verification and resolves a broad set of storage, upgrade, security, and management issues.
VMware vCenter 9.1.1.0 | 03 SEP 2026 | Build 25712839 What's New Automated Secure Boot Platform Key (PK) Remediation: To address Microsoft 2011 Secure Boot certificate expirations, as detailed in Broadcom knowledge base article 423893, VCF 9.1.1.0 introduces three new capabilities to simplify Platform Key (PK) remediation: vCenter Alarm: Proactively warns administrators when Secure Boot-enabled, powered-on virtual machines have an out-of-date NULL PK. This per-VM alarm is triggered once vCenter and the ESX host are upgraded to 9.1.1.0. Silent PK Update in ESX: Automatically updates the out-of-date NULL PK on Secure Boot-enabled virtual machines that have no virtual Trusted Platform Module (vTPM) during a guest reboot. Capsule PK Update: Enables a secure mechanism to safely update the out-of-date NULL PK on Secure Boot-enabled, vTPM-enabled Windows virtual machines during a guest reboot without interrupting TPM-based applications. The Capsule PK update driver triggering the PK update is available starting in VMware Tools 13.1.5 for supported Windows versions, except Windows Server 2016, Windows 10 64-bit 22H2, and 1809, which will be supported in a future VMware Tools release. For the Capsule PK update, the July 2026 Windows Cumulative Update or later is required. You must install this cumulative update before installing or upgrading VMware Tools to version 13.1.5 to allow the installation of the PK update driver, except for Windows Server 2025, Windows 11 25H2, and 24H2. VM-VM anti-affinity and affinity rules through compute policies: You can use compute policies to create VM-VM anti-affinity rules that distribute VMs across separate hosts for resiliency, and VM-VM affinity rules that collocate VMs on the same host for low latency. This functionality applies to traditional virtual machines and to virtual machines created through VM Service. In the VM spec file, you can configure the strictness of a rule as either required (hard) or preferred (soft) during initial VM placement. However, only the preferred setting is supported during runtime. For more information, see vSphere Compute Policies. Photon RPMs are upgraded to the latest versions for improved security. Distributed Resource Scheduler (DRS) and High Availability (HA) support for Memory Tiering: With VCF 9.1.1, Memory Tiering supports DRS and HA. In clusters with Memory Tiering activated, vSphere HA admission control tracks DRAM as an independent resource alongside total memory to make sure that the cluster retains sufficient DRAM capacity for virtual machines restart after a host failure. This capability prevents failover operations from silently failing due to insufficient DRAM. For more information, see Memory Tiering and HA Admission Control. Product Support Notes Removal of the lstool script: The ls_update_certs.py script is removed, because it is only supported on vCenter 6.x and 7.x versions. You can use the Lookup Service Doctor (lsdoctor) tool instead, as described in Broadcom knowledge base article 320837. vCenter enforces MethodActions alarms to run on behalf of the user who configures the alarm: With VCF 9.1.1, new vCenter alarms configured with the MethodAction object can only be executed on behalf of existing users with current, valid permissions. Alarms configured by users who have been deleted or had their privileges revoked are blocked and a com.vmware.vc.AlarmMethodActionBlockedEvent event is posted on the target object. You can control the enforcement behavior by using the Advanced Setting vpxd.alarm.methodActionMode in vCenter and selecting a mode, such as vpxd.alarm.methodActionMode = flexible | strict | legacy: flexible (default): Enforces user identity and privilege checks for new alarms. Existing alarms continue to fire without disruption. strict: All MethodActions require valid user credentials and privilege checks. Blocked actions post a com.vmware.vc.AlarmMethodActionBlockedEvent event. legacy: Actions run impersonating the vpxd service account. If a MethodAction is blocked in strict mode, a com.vmware.vc.AlarmMethodActionBlockedEvent event is posted on the target object. Re-save the alarm to register fresh credentials. Build Details VMware vCenter 9.1.1.0 Download Filename: VMware-vCenter-Server-Appliance-9.1.1.0.25712839-patch-FP.iso Build: 25712839 Download Size: 7717 MB SHA256 checksum: d281358465b5cb770d15ccfad5be528e840988986123f401a5039666f0fecbc1 Quick Patch: No CVEs: N/A Applying the Patch Log in to the Broadcom Support Portal to download this patch, depending on your entitlement. For download instructions, see Download Broadcom products and software. For more information on using the vCenter shells, see Broadcom knowledge base article 2100508. For information about deploying, converging, upgrading or patching your environment to 9.1.1, see Getting to 9.1.1. For VCF environments, you apply this patch by using VCF Operations. See Upgrade or Patch an Individual VCF Component. For VMware vSphere Foundation environments, see Upgrading the vCenter Appliance. Resolved Issues Storage Issues You cannot clone a virtual machine with Raw Device Mappings (RDM) disk to a VM with thin flat disk When you clone a VM with an RDM disk and select the thin provisioning option, the resulting disk is always converted to a thick flat disk. Auto Deploy Issues Deploying a stateful ESX host by using Auto Deploy fails with "Certificate path is missing for host with id" Due to a timing conflict between the configuration of distributed virtual switches (DVS) and the Auto Deploy notification code, deploying a stateful ESX host by using Auto Deploy with a Host Profile configured to add the host to a DVS might fail. In the vSphere Client, you see an error such as Certificate path is missing for host with id. vCenter and vSphere Client Issues Generating a hardware compatibility report in the vSphere Client fails with an error for the Internet connection In the vSphere Client, when you generate a host hardware compatibility report, the task might fail with an error such as Check vCenter Server Appliance internet connection to the VMware Verification Service at 'vvs.esp.vmware.com' and 'auth.esp.vmware.com'. The issue occurs when the hardware compatibility check requires online search or the Sync Compatibility Data operation in the vSphere Lifecycle Manager cannot complete. You see an error that a VCF license cannot be assigned to a vCenter instance If the UUID of the vCenter instance you are licensing by using the VCF Operations UI is upper case, the operation fails with an error such as: This license could not be assigned to the selected vCenter System. Check the network connection from the selected vCenter system to the license server and try again. Please refer to KB article 424533 for more information. The fix makes sure that the vCenter UUID is always lower case. vCenter vpxd service might intermittently fail during backup operations due to a missing InstanceUUID in a virtual machine A missing InstanceUUID parameter in a virtual machine during VM backup operations with a 3-rd party tool might cause the vpxd service to fail with a core.vpxd-worker dump and Program terminated with signal SIGABRT, Aborted error. You do not see service accounts in the Global Permissions page in the vSphere Client Since service account permissions are not customer-managed, service accounts are filtered out from the Global Permissions page in the vSphere Client. The page also excludes VCF reserved groups. You can retrieve all accounts for auditing or any other purpose by using CLI/API. Applying password expiry and lockout policies for the vCenter Single Sign-On (SSO) administrator account might affect existing automation and integrations The vCenter SSO administrator account enforces no password expiration or lockout policies by default. Applying these security policies globally might affect existing automation, integrations, and day-to-day operations. vCenter 9.1.1.0 introduces an opt-in/opt-out mechanism for the SSO administrator account password policy through a vCenter API endpoint. By default, the account remains opted out, preserving the existing behavior where no expiration or lockout is enforced. If you require strict compliance, you can opt in to apply expiry and lockout policies to the account. The VCF Operations UI does not expose this setting in 9.1.1.0. You can use only the vCenter API. This issue is resolved in this release. If you opt in for password expiry and lockout policies for the vCenter SSO administrator account, you can use the following example: curl -sk -X PATCH \ "https://10.161.46.164/api/identity/admin/administrator/password-policy" \ -H "vmware-api-session-id: ${session}" \ -H "Content-Type: application/json" \ -d '{"enable_expiry_policy": true, "enable_lockout_policy": true}' After a VCF certificate refresh, you see stale data for removed hosts in vSphere Configuration Profiles (VCP) cluster configurations Following a VCF certificate refresh, the VCP inventory monitoring service loses its cached host association information. If a host removal event occurs before the cache is rebuilt, the system fails to identify the host association and skips the necessary configuration cleanup. As a result, stale host-specific and host-override sections remain in the cluster configuration. The vSphere Statistics (vstats) service repeatedly logs a false-positive ERROR-level message about a missing discovery configuration for host-based metrics The vstats provider orchestrator might incorrectly attempt to register the ESX host metrics provider with the generic discovery manager, even though host providers use a push-based streaming model and do not require generic discovery. As a result, the provider reports an error multiple times per minute, generating roughly 5,000 false-positive error events per day in Log management. The vstats service remains fully functional, only the logging behavior is affected. Content library synchronization occasionally fails due to a reported missing file, even though the library is fully in sync and the file exists on the publisher The pagination queries during a content library sync might not use a fully deterministic sort order. As a result, for libraries containing more than 100 items, some file records belonging to the same item might be returned in an inconsistent order across paginated queries. Occasionally, a file that is already present, might be identified as missing and scheduled for deletion during a subscribed library sync. The pagination queries used during library-item sync now sort deterministically by item, version, and file identifiers, ensuring files are consistently accounted for across paginated results. A vApp does not retain changes to some settings after a restart of vCenter or the VPXD service Some settings of vApps such as the start order and the IP allocation are not updated in the vCenter database when they are changed. As a result, they might revert to previous values after a reboot of vCenter or a restart of the VPXD service. vCenter upgrade from 8.0.x or 9.0.x to 9.1.0 fails during the import of vSphere Lifecycle Manager while attempting database schema upgrade Orphaned database records in the vSphere Lifecycle Manager database, specifically in the pm_recommendation_spec table, might cause vCenter upgrade from 8.0.x or 9.0.x to 9.1.0 to fail. In the Virtual Appliance Management Interface, you see an error such as Error attempting Upgrade Database Schema. Please check vcintegrity migration logs for details. vCenter 9.1.0.0 introduces a strict foreign key constraint, FK_PM_RECOMMENDATION_SPEC, to harden database integrity and the Postgres engine blocks schema changes because existing orphaned data violates the constraint. Converging vSphere environments to VCF 9.1 might complete with errors due to duplicate DNS servers In the vCenter Appliance Management Interface (VAMI), you can set duplicate DNS Server settings, which leads to errors after converging vSphere environments to VCF 9.1. The fix removes duplicates and prevents error propagation for invalid DNS addresses. You see an error 'HTTP Error 403: Forbidden' in the vSphere Client while downloading VIBs Upgrading or remediating ESX hosts might fail with an error HTTP Error 403: Forbidden in the vSphere Client while downloading VIBs because of an issue with file permissions. OpenLDAP login to vCenter fails after upgrade to VCF 9.1 due to a missing attribute vCenter requires the serviceAccount attribute for OpenLDAP providers and if such is missing, OpenLDAP login fail after an upgrade to VCF 9.1. Some vCenter services or operations might fail due to machine account password mismatch If the machine account password stored in the VMware Directory Service (VMDIR) database does not match the password used by a given vCenter service, such services fail to start or some vCenter operations fail, but you do not see a notification or informative error message. The fix adds the error message Machine Account password mismatch. Refer to KB 316608, providing a vCenter alarm on the condition and steps for remediation. You can accidentally remove a node from Enhanced Linked Mode (ELM) topology by running the cmsso-util unregister command on the same vCenter instance When you run the cmsso-util unregister command from a vCenter instance, you might accidentally unregister that same vCenter instead of another node in the topology. The fix adds a validation that the cmsso-util unregister command does not target the vCenter instance from which it is run. Running the cmsso-util unregister command for a vCenter that is not powered off causes an inconsistent state of the vCenter If you do not power off or shut down a vCenter instance before running the cmsso-util unregister command, as required, the operation fails and the vCenter instance is in an inconsistent state. The fix adds a pre-check to make sure the vCenter being unregistered is powered off before triggering the cmsso-util unregister command for it from another linked vCenter instance. Miscellaneous Issues After renewal, you see Solution User certificates with 2-year validity instead of the expected 10 years When you use the vSphere Certificate Manager Utility to renew or replace a solution user certificate, if you set the option Do you wish to generate all certificates using configuration file to Y, the new certificates default to a 2-year validity period. If the option is set to N, the solution user certificates are generated with a validity period of 10 years, which is the expected and documented behavior. vSphere High Availability failover fails on virtual machines for appliances such as vCenter and Fleet Manager SDCC Manager uses the vSphere API call migrateManagementNetwork to migrate VMs for appliances such as vCenter and Fleet Manager from a standard switch to a distributed virtual switch (VDS). The API might fail to set the persist path of the dvport used by the VMs. As a result, if the hosting ESX node is rebooted, HA cannot restore the VM on another host: loadDVPort fails with ENOENT / PlatformConfigFault, HA rolls back the failover, and the VM remains powered off. Extension authentication by using LoginExtensionBySubjectName API fails after upgrading vCenter to version 9.1.1.0 After upgrading vCenter to version 9.1.1.0, if you use the LoginExtensionBySubjectName API for extension authentication, the task fails with an InvalidLogin SOAP fault. In the vpxd.log, you see a message similar to: [SessionManagerMo::LoginExtensionBySubjectName] Login failed for extension <extension-key>: certificate not pinned in VCDB. Use SetExtensionCertificate to register the extension certificate. Extensions using LoginExtensionByCertificate or SSO-based authentication and other vCenter Server management operations are not affected. The failure results from vCenter enforcing certificate pinning on LoginExtensionBySubjectName, which causes extensions that have not registered their TLS certificate by SetExtensionCertificate to receive InvalidLogin faults after a vCenter upgrade. The fix effectively removes the deprecated LoginExtensionBySubjectName API. Cloning a virtual appliance (vApp) might skip a permission check when the target ESX host is not specified When cloning a vApp and specifying a target ESX host in the CloneSpec API, vCenter requires the VApp.Create permission on that host. But when the target host is not specified, the compute resource is implicitly determined from the owner of the target Resource Pool or vApp. In such cases, the permission check is skipped, allowing a vApp to be cloned onto a host or cluster that lacks the VApp.Create permission, as long as the permissions on other objects, like Resource.AssignVAppToPool on the target resource pool, are satisfied. The fix enforces the VApp.Create permission. You cannot clone vApps onto compute resources without the VApp.Create permission. If the ESX host selected to create an NFC session during a File Manager backup is entering maintenance mode, the backup might fail During a File Manager backup, while downloading VMDKs from a datastore browser, an NFC session is created with the selected ESX host. If the host is entering maintenance mode, the NFC session fails and as a result, the backup fails. The fix prevents the selection of ESX hosts which are entering or exiting maintenance mode when creating an NFC session to download VMDKs during a File Manager backup. Upgrade Issues Executing a VCF 9.1 upgrade precheck prematurely enables cgroupv2 in the OS configuration and might cause unpredictable service behavior if the source machine restarts When performing an upgrade precheck targeting VCF version 9.1 either by Reduced Downtime Upgrade (RDU) or regular upgrade, the OS configuration for cgroupv2 might be altered prematurely on the source node. Restarting the source machine after the precheck might disrupt operational services such as the vc-ws1a-broker service in vCenter. vCenter CLI upgrade fails with an HTTP 401 Unauthenticated error during the source vCenter version check phase When performing a vCenter upgrade from a version earlier than 9.0 or from 9.0.x to 9.1 by using the Command Line Interface (CLI), if an Active Directory (AD) domain is configured as the default identity source in the vCenter Single Sign-On (SSO) configuration, the process might fail. The upgrade tool incorrectly attempts to authenticate the local root account against the AD identity provider instead of the local SSO domain (vsphere.local), resulting in an authentication failure. You see “Exception occurred in postInstallHook for B2B-patching” error during upgrade from vCenter 9.0.2.0 to 9.1 If you follow Broadcom knowledge base article 414489 to modify the /usr/lib/vmware-trustmanagement/config/trustmanagement-vlsi.xml file during an upgrade to vCenter 9.0.2.0, you might see an error when upgrading to version 9.1. The error occurs because VCF 9.1 contains an updated version of the trustmanagement-vlsi.xml file and if the file was modified in 9.0.2.0, the upgrade to 9.1 leaves the old 9.0.2.0 trustmanagement-vlsi.xml in place. As a result, the vCenter vmware-trustmanagement service cannot start. For upgrades to VCF 9.1, make sure you revert /usr/lib/vmware-trustmanagement/config/trustmanagement-vlsi.xml to the default before the upgrade. Backup and Restore SSH keys on remote servers are removed during SFTP backup When a SFTP backup schedule is created, an SSH key of the vCenter instance is added to ~/.ssh/authorized_keys on the remote server, but the corresponding SSH key is not removed from the remote server. The fix removes stale SSH keys from remote servers during the first backup triggered after upgrade to vCenter 9.1.1.0. File-based backup and restore transfers to external FTPS, HTTPS, or SFTP servers execute without authenticating the target server identity In vCenter 9.1.1.0, file-based backup and restore enhances target server identity verification and auditing for FTPS, HTTPS, and SFTP protocols. In default mode (validateCerts: false), data transfers remain backward-compatible and execute as before, while a background probe checks the server identity and records a non-blocking advisory in: - vCenter Appliance Management Interface (VAMI) backup activity details - the restore wizard review page - audit logs if the server is unverified. If you enable strict validation (validateCerts: true), connections strictly enforce peer identity verification, leveraging custom CA certificates (br_servercert.crt), the system CA trust store (ca-bundle.crt), or pinned SSH host keys (br_known_hosts), and fail the connection if unverified. For more information on how to prevent unverified target server advisories or to enable strict peer verification, see Broadcom knowledge base article 310399. Known Issues vCenter upgrade or patch to version 9.1.1 fails during the prechecks with error message: Unable to run vCenter NTP server check The NTP precheck fails on vCenter instances configured with a non-UTC time zone. Workaround: To change the configured time zone to UTC, follow the steps in Broadcom knowledge base article 455439. Migration Issues After Cross vCenter vMotion migration, powered-off virtual machines are always placed on the same host In the vSphere Client, when you navigate to Home > Hosts and Clusters, right-click to select a cluster and click Import VMs, powered-off VMs are always relocated to the same target host in the selected cluster, even when the migration is split into multiple distinct tasks over time. Workaround: Manually pick a different target host. API/CLI Issues vSphere Automation API does not honor network mappings in DeploySpec When you specify network mapping entries in a DeploySpec, the API does not honor the mapping and selects a default network instead. In the vpxd logs, you see an error such as Host did not have any virtual network defined (vim.fault.OvfNoHostNic). As a result, the VM does not receive the correct network that you specified. Workaround: Change the network settings of the VM after it has finished deploying by either the vSphere Client or SDK. You see a syntax warning message when using the certificate-manager CLI When you manually run a certificate-manager CLI script, you might see a SyntaxWarning message due to internal updates. The warning has no effect on the functionality of the certificate-manager CLI utility. Workaround: None. Ignore the warning. Upgrade Issues A reset of the vSphere Lifecycle Manager database might cause data loss in the Supervisor If the vSphere Lifecycle Manager database in your environment is reset before upgrading vCenter from versions 8.0 Update 3 and later or 9.0.x to 9.1.0 or 9.1.1, the upgrade might cause data loss in the Supervisor. To avoid data loss, before a vCenter upgrade, you must first check your environment and take mitigation steps, if necessary. Workaround: See Broadcom knowledge base article 455737 for instructions how to check if your environment is affected and for mitigation steps. vCenter shows "Virtual Machine UEFI Secure Boot Platform Key is out of date." warning for the license server After you patch your vCenter from version 9.1.0.x to 9.1.1, in the vSphere Client where the license server is deployed, you see the message Virtual Machine UEFI Secure Boot Platform Key is out of date. in the issues and alarms section. The alarm appears when you have license servers in version 9.1.0.x or license servers patched to version 9.1.1. This alert is not critical and has no impact on the boot or the functionalities of your license server. Workaround: To resolve the alarm, from the vSphere Client, upgrade the compatibility of the license server VM to ESXi 6.7 and later by following the Upgrade the Compatibility of a Virtual Machine Manually procedure. Upgrade from vCenter 8.0 Update 3j to 9.1.1.0 might fail in environments with Windows 2016 server In some environments with Windows Server 2016 Datacenter (Build 10.0.14393), when you use the vCenter installer to upgrade from vCenter 8.0 Update 3j to 9.1.1.0, the operation might fail in stage 1 with an error such as Failed to send file [disk-0.vmdk] to the host [lvnvcfspatn02.lvn.broadcom.net], please check the network connection). Workaround: Update the Windows Server version. vCenter and vSphere Client Issues In the vSphere Client, you see a License Inventory Monitoring alarm After you assign an override license to an ESX hosts of version 8.x, the license usage calculation might incorrectly include the usage from the ESXi 8.x hosts to the license assigned to the managing vCenter instance. As a result, in the vSphere Client you see a License Inventory Monitoring alarm. The license calculation discrepancy affects only the API responsible for the vCenter alert. The overall core count displayed in the Licenses tab in the vSphere Client is correct and matches the license usage metrics in VCF Operations. Workaround: See Broadcom knowledge base article 456737.
Original source - Jul 29, 2026
- Date parsed from source:Jul 29, 2026
- First seen by Releasebot:Nov 25, 2026
VMware vCenter Server by Broadcom
VMware vCenter 9.1.0.0300 Release Notes
VMware vCenter Server releases version 9.1.0.0300, resolving CVE-2026-59310. The patch also includes guidance on a known upgrade risk that could cause Supervisor data loss after a vSphere Lifecycle Manager database reset.
Introduction VMware vCenter 9.1.0.0300 | 29 JUL 2026 | Build 25629530 Check for additions and updates to these release notes. What's New This release resolves CVE-2026-59310. For more information on this vulnerability and its impact on Broadcom products, see VMSA-2026-0006. Build Details VMware vCenter 9.1.0.0300 Build Details Download Filename: VMware-vCenter-Server-Appliance-9.1.0.0300.25629530-patch-FP.iso Build: 25629530 Download Size: 8629.3 MB SHA256 checksum: 759a55bd4c0029503c61814bf5f61f73e54fa07339915d6f0107150f868b5f2f Quick Patch: No CVEs: CVE-2026-59310 Applying the Patch Log in to the Broadcom Support Portal to download this patch, depending on your entitlement. For download instructions, see Download Broadcom products and software. For more information on using the vCenter shells, see Broadcom knowledge base article 2100508. For VCF environments, you apply this patch by using VCF Operations. See Upgrade or Patch an Individual VCF Component. For VMware vSphere Foundation environments, see Upgrading the vCenter Appliance. Known Issues A reset of the vSphere Lifecycle Manager database might cause data loss in the Supervisor If the vSphere Lifecycle Manager database in your environment is reset before upgrading vCenter from versions 8.0 Update 3 and later or 9.0.x to 9.1.0 or 9.1.1, the upgrade might cause data loss in the Supervisor. To avoid data loss, before a vCenter upgrade, you must first check your environment and take mitigation steps, if necessary. Workaround: See Broadcom knowledge base article 455737 for instructions how to check if your environment is affected and for mitigation steps.
Original source - Jul 29, 2026
- Date parsed from source:Jul 29, 2026
- First seen by Releasebot:Nov 25, 2026
- Modified by Releasebot:Nov 25, 2026
VMware vCenter Server by Broadcom
VMware vCenter 9.0.2.0100 Release Notes
VMware vCenter Server releases version 9.0.2.0100, resolving two security vulnerabilities. The patch is available through the Broadcom Support Portal, with separate guidance for VCF and VMware vSphere Foundation environments.
Introduction
VMware vCenter 9.0.2.0100 | 29 JUL 2026 | Build 25629525 Check for additions and updates to these release notes.
What's New
This release resolves CVE-2026-59309 and CVE-2026-59310. For more information on these vulnerabilities and their impact on Broadcom products, see VMSA-2026-0006.
Build Details
VMware vCenter 9.0.2.0100
Download Filename:
VMware-vCenter-Server-Appliance-9.0.2.0100.25629525-patch-FP.isoBuild: 25629525
Download Size: 9167.6 MB
SHA256 checksum:
5fa6818ae0d625ec7451ed49eb171c8ee2640f436c8830eba8dc58e897e8a79aCVEs
CVE-2026-59309, CVE-2026-59310
Applying the Patch
Log in to the Broadcom Support Portal to download this patch, depending on your entitlement.
For download instructions, see Download Broadcom products and software.
For more information on using the vCenter shells, see Broadcom knowledge base article 2100508.
For VCF environments, you apply this patch by using VCF Operations. See Upgrade or Patch an Individual VCF Component.
For VMware vSphere Foundation environments, see Upgrading the vCenter Appliance.
Original source - Jul 29, 2026
- Date parsed from source:Jul 29, 2026
- First seen by Releasebot:Nov 25, 2026
VMware vCenter Server by Broadcom
VMware vCenter 8.0 Update 3k Release Notes
VMware vCenter Server releases 8.0 Update 3k with fixes for two security vulnerabilities and several vSphere Client issues, including incorrect resource limits and large datastore capacity displays. Upgrades from this update to version 9.1 are not yet supported.
Introduction VMware vCenter 8.0 Update 3k | 29 JUL 2026 | ISO Build 25600417 Check for additions and updates to these release notes. What's New This release resolves CVE-2026-59309 and CVE-2026-59310. For more information on these vulnerabilities and their impact on Broadcom products, see VMSA-2026-0006. Upgrade Notes Upgrade from vCenter 8.0 Update 3k to vCenter 9.1.0 or any patch based on 9.1.0 is not supported. Forward upgrade path to 9.1.x will be available in a future 9.1.x release. For more details on vSphere back-in-time support for upgrade, converge and import, see this blog post. Build Details VMware vCenter 8.0 Update 3k Download Filename: VMware-vCenter-Server-Appliance-8.0.3.01000-25600417-patch-FP.iso Build: 25600417 Download Size: 8532.1 MB sha256checksum: a74f93a8a4e50dabbbc8db8c64767cd9a8647c78c56003b541a41d4984728ba4 CVEs: CVE-2026-59309, CVE-2026-59310 Download and Installation Log in to the Broadcom Support Portal to download this patch. See these KBs for details on the authenticated online and offline download: 390121, 390098, and 389276. For more information on using the vCenter Server shells, see VMware knowledge base article 2100508. For more information on patching vCenter Server, see Patching and Updating vCenter Server 8.0 Deployments. For more information on staging patches, see Upgrading the vCenter Server Appliance. Known Issues from Previous Releases Installation, Upgrade, and Migration Issues If you do not open port 9087 in your firewall between ESXi hosts and vCenter, compliance checks and vSphere HA might fail after vCenter update to 8.0 Update 3 Starting from 8.0 Update 3, the vSphere Lifecycle Manager downloads updates for ESXi hosts by a HTTPS connection to the vCenter instance on port 9087. If you do not open port 9087 in your firewall between ESXi hosts and vCenter, you might see compliance check errors. For example, in the lifecycle.log you see messages such as: <Timestamp> In(14) lifecycle[2112988]: Downloader:373 Opening https://<VC-FQDN>:9087/vum/repository/hostupdate/__micro-depot__vendor-DEL__DEL-ESXi-8.0-Addon-cumulative_metadata__index__.xml for download <Timestamp> Wa(12) lifecycle[2112988]: Downloader:210 Download failed: <urlopen error timed out>, 9 retry left... In addition, vSphere HA might fail to start. Workaround: Open port 9087 in your firewall between ESXi hosts and vCenter by using the TCP protocol. In a mixed vSphere 7.x and 8.x environment with vSphere DRS, an incompatible virtual machine might prevent an ESXi host to enter maintenance mode In a mixed vSphere 7.x and 8.x environment with DRS, a VM of 7.x version that is not compatible with ESXi 8.0 Update 1 and later might prevent an ESXi 8.0 Update 1 host to enter maintenance mode. The issue is specific for virtual machines with VMDK on a vSphere Virtual Volumes datastore. In the vSphere Client, you see an error such as Waiting for all VMs to be powered off or suspended or migrated. In a DRS cluster check the Faults page on the DRS tab for troubleshooting. Workaround: Power-off the incompatible virtual machine. vSphere Lifecycle Manager baseline check compliance fails on ESXi hosts of version 7.0 GA in a vCenter 8.0 Update 3 system Due to a limitation of the esxupdate memory resource pool on 7.0 GA ESXi hosts, a vSphere Lifecycle Manager baseline check compliance scan might fail on 7.0 GA ESXi host in a vCenter 8.0 Update 3 system with error such as The host returns esxupdate error codes: -1. The host esxupdate.log contains an error such as: <Timestamp> esxupdate: <PID>: esxupdate: ERROR: vmware.runcommand.RunCommandError: Error running command '['/sbin/smbiosDump']': [Errno 12] Cannot allocate memory The vmkernel.log contains error such as: <Timestamp> cpu0:<PID>)Admission failure in path: host/vim/vmvisor/esxupdate/python.<PID>:python.<PID>:uw.<PID> This issue is specific for 7.0 GA ESXi hosts, as esxupdate memory allocation is increased in 7.0 Update 1 and later. Workaround: Use an ISO upgrade baseline to upgrade the 7.0 GA ESXi hosts to a 8.x version or revert the vCenter system back to version 7.0 and upgrade the hosts to a version of 7.0 Update 1 and later. You see an error Failed to get ceip status in the Virtual Appliance Management Interface (VAMI) during update to vCenter Server 8.0 Update 1 During an update, vCenter stops and restarts the VMDir service and within this interval, if you try to log in to the VAMI, you might see an error such as Failed to get ceip status. This is expected and does not indicate an actual issue with the vCenter system. Workaround: Wait for the VMDir service to restart and refresh the Virtual Appliance Management Interface. If you click NEXT before the progress bar reaches 100% in a vCenter Server Lifecycle Manager plug-in upgrade, the Server Lifecycle Manager service fails In the Upgrade Plug-in step of the vCenter Server Lifecycle Manager plug-in upgrade wizard, if you click NEXT before the progress bar reaches 100%, the Server Lifecycle Manager service fails. Workaround: Wait for the progress bar to reach 100% before you click NEXT. vCenter upgrade or update to 8.0 Update 2a or later fails during precheck with the error "VMCA root certificate validation failed" If your vCenter system has a legacy VMCA root certificate dating back to version 5.x which does not have the Subject Key Identifier (SKID) extension, upgrades and updates to vCenter 8.0 Update 2 and later fail because the OpenSSL version 3.0 in 8.0 Update 2 is not compatible with legacy root certificates. vCenter Server 8.0 Update 2a adds a precheck to detect this issue and shows the error message VMCA root certificate validation failed if the source vCenter has VMCA root certificate without SKID. Workaround: Regenerate a VMCA root certificate by following the steps in VMware knowledge base article 94840. You see a "vc.health.error.dbjob3" warning after a vCenter upgrade In the vSphere Client or the in Virtual Appliance Management Interface, you might see the warning vc.health.error.dbjob3 after a vCenter upgrade although the vCenter overall health status is green. This issue does not affect vCenter operations, it can only affect historical statistics when some data does not roll up for more than 72 hours. Workaround: See Delete old tasks, events and statistics data in vCenter Server 5.x, 6.x, 7.x and 8.x how to clear stats data, if not relevant anymore. Update to vCenter 8.0 Update 3 might fail with an error "Destination path '/storage/analytics/stage/...' already exists" Starting with vCenter 8.0 Update 3, the analytics service stores telemetry log files in a new directory. In rare cases, if previous update attempts had failed and reverted, when patching to vCenter 8.0 Update 3, the attempt to copy the telemetry log files to the new location might fail because these files already exist from a prior patching attempt. In the patchrunner.log file, you see an error such as Destination path '/storage/analytics/stage/XXXXXX_processed_logs' already exists. Workaround: Delete all files under /storage/log/vmware/analytics/stage, /storage/log/vmware/analytics/prod, /storage/analytics/stage, and /storage/analytics/prod, and retry the update. You see a security warning for the ESX Agent Manager configuration during the pre-check phase of a vCenter upgrade During the pre-check phase of a vCenter update or upgrade, in the vSphere Client and logs, you might see an error such as: Source ESX Agent Manager Configuration contains URLs that are not trusted by the System! Verify following URLs and their respective statuses and follow KB 93526. Workaround: For more information, see VMware knowledge base article 93526. Firmware compliance details are missing from a vSphere Lifecycle Manager image compliance report for an ESXi standalone host Firmware compliance details might be missing from a vSphere Lifecycle Manager image compliance report for an ESXi standalone host in two cases: - You run a compliance report against a standalone host managed with a vSphere Lifecycle Manager image from vSphere Client and then navigate away before the compliance report gets generated. - You trigger a page refresh after the image compliance reports are generated. In such cases, even when you have the firmware package available in the Desired State, the firmware compliance section remains empty when you revisit or refresh the vSphere Client browsing session. If you use GET image compliance API, then firmware compliance details are missing from the response. Workaround: Invoke the image compliance scan for a standalone host managed with a vSphere Lifecycle Manager image by using the vSphere Client and do not navigate away or refresh the browser. For API, use the Check image compliance API for fetching the firmware details as apposed to GET image compliance. If you apply a host profile using a software FCoE configuration to an ESXi 8.0 host, the operation fails with a validation error Starting from vSphere 7.0, software FCoE is deprecated, and in vSphere 8.0 software FCoE profiles are not supported. If you try to apply a host profile from an earlier version to an ESXi 8.0 host, for example to edit the host customization, the operation fails. In the vSphere Client, you see an error such as Host Customizations validation error. Workaround: Disable the Software FCoE Configuration subprofile in the host profile. URL-based patching or file-based backup of vCenter 8.0 Update 2 might fail due to OpenSSL noncompliance to Federal Information Processing Standards (FIPS) With vCenter 8.0 Update 2, OpenSSL works only with Diffie-Hellman parameters compliant to NIST SP 800-56A and FIPS 140-2. For URL-based patching or file-based backup of vCenter 8.0 Update 2 systems, FTPS servers in your environment must support the following ciphers: OPENSSL CIPHER SUITE | NAME AT-TLS CIPHER SUITE NAME | HEXADECIMAL VALUE DHE-RSA-AES256-SHA | TLS_DHE_RSA_WITH_AES_256_CBC_SHA | 39 DHE-DSS-AES256-SHA | TLS_DHE_DSS_WITH_AES_256_CBC_SHA | 38 AES256-SHA | TLS_RSA_WITH_AES_256_CBC_SHA | 35 EDH-RSA-DES-CBC3-SHA | TLS_DHE_RSA_WITH_3DES_EDE_CBC_SHA | 16 EDH-DSS-DES-CBC3-SHA | TLS_DHE_DSS_WITH_3DES_EDE_CBC_SHA | 13 DES-CBC3-SHA | TLS_RSA_WITH_3DES_EDE_CBC_SHA | 0A DHE-RSA-AES128-SHA | TLS_DHE_RSA_WITH_AES_128_CBC_SHA | 33 DHE-DSS-AES128-SHA | TLS_DHE_DSS_WITH_AES_128_CBC_SHA | 32 AES128-SHA | TLS_RSA_WITH_AES_128_CBC_SHA | 2F Workaround: Make sure your file servers are FIPS compliant. VMNICs might be down after an upgrade to ESXi 8.0 If the peer physical switch of a VMNIC does not support Media Auto Detect, or Media Auto Detect is disabled, and the VMNIC link is set down and then up, the link remains down after upgrade to or installation of ESXi 8.0. Workaround: Use either of these 2 options: - Enable the option media-auto-detect in the BIOS settings by navigating to System Setup Main Menu, usually by pressing F2 or opening a virtual console, and then Device Settings > <specific broadcom NIC> > Device Configuration Menu > Media Auto Detect. Reboot the host. - Alternatively, use an ESXCLI command similar to: esxcli network nic set -S <your speed> -D full -n <your nic>. With this option, you also set a fixed speed to the link, and it does not require a reboot. After upgrade to ESXi 8.0, you might lose some nmlx5_core driver module settings due to obsolete parameters Some module parameters for the nmlx5_core driver, such as device_rss, drss, and rss, are deprecated in ESXi 8.0 and any custom values, different from the default values, are not kept after an upgrade to ESXi 8.0. Workaround: Replace the values of the device_rss, drss and rss parameters as follows: - device_rss: Use the DRSS parameter. - drss: Use the DRSS parameter. - rss: Use the RSS parameter. Miscellaneous Issues In a vCenter Server system with DPUs, if IPv6 is disabled, you cannot manage DPUs Although the vSphere Client allows the operation, if you disable IPv6 on an ESXi host with DPUs, you cannot use the DPUs, because the internal communication between the host and the devices depends on IPv6. The issue affects only ESXi hosts with DPUs. Workaround: Make sure IPv6 is enabled on ESXi hosts with DPUs. You might see 10 min delay in rebooting an ESXi host on HPE server with pre-installed Pensando DPU In rare cases, HPE servers with pre-installed Pensando DPU might take more than 10 minutes to reboot in case of a failure of the DPU. As a result, ESXi hosts might fail with a purple diagnostic screen and the default wait time is 10 minutes. Workaround: None. If you have an USB interface enabled in a remote management application that you use to install ESXi 8.0, you see an additional standard switch vSwitchBMC with uplink vusb0 Starting with vSphere 8.0, in both Integrated Dell Remote Access Controller (iDRAC) and HP Integrated Lights Out (ILO), when you have an USB interface enabled, vUSB or vNIC respectively, an additional standard switch vSwitchBMC with uplink vusb0 gets created on the ESXi host. This is expected, in view of the introduction of data processing units (DPUs) on some servers but might cause the VMware Cloud Foundation Bring-Up process to fail. Workaround: Before vSphere 8.0 installation, disable the USB interface in the remote management application that you use by following vendor documentation. After vSphere 8.0 installation, use the ESXCLI command esxcfg-advcfg -s 0 /Net/BMCNetworkEnable to prevent the creation of a virtual switch vSwitchBMC and associated portgroups on the next reboot of host. See this script as an example: ~# esxcfg-advcfg -s 0 /Net/BMCNetworkEnable The value of BMCNetworkEnable is 0 and the service is disabled. ~# reboot On host reboot, no virtual switch, PortGroup and VMKNIC are created in the host related to remote management application network. If an NVIDIA BlueField DPU is in hardware offload mode disabled, virtual machines with configured SR-IOV virtual function cannot power on NVIDIA BlueField DPUs must be in hardware offload mode enabled to allow virtual machines with configured SR-IOV virtual function to power on and operate. Workaround: Always use the default hardware offload mode enabled for NVIDIA BlueField DPUs when you have VMs with configured SR-IOV virtual function connected to a virtual switch. ESXi hosts might become unresponsive, and you see a vpxa dump file due to a rare condition of insufficient file descriptors for the request queue on vpxa In rare cases, when requests to the vpxa service take long, for example waiting for access to a slow datastore, the request queue on vpxa might exceed the limit of file descriptors. As a result, ESXi hosts might briefly become unresponsive, and you see a vpxa-zdump.00* file in the /var/core directory. The vpxa logs contain the line Too many open files. Workaround: None. The vpxa service automatically restarts and corrects the issue. Networking Issues Overlapping hot-add and hot-remove operations for DirectPath I/O devices might fail With vSphere 8.0 Update 1, by using vSphere API you can add or remove a DirectPath I/O device without powering off VMs. However, if you run several operations at the same time, some of the overlapping tasks might fail. Workaround: Plan for 20 seconds processing time between each hot-add or hot-remove operation for DirectPath I/O devices. Hot adding and removing of DirectPath I/O devices is not automatically enabled on virtual machines With vSphere 8.0 Update 1, by using vSphere API you can add or remove a DirectPath I/O device without powering off VMs. When you enable the hotplug functionality that allows you to hot add and remove DirectPath I/O devices to a VM, if you use such a VM to create an OVF and deploy a new VM, the new VM might not have the hotplug functionality automatically enabled. Workaround: Enable the hotplug functionality as described in Hot-add and Hot-remove support for VMDirectPath I/O Devices. You cannot set the Maximum Transmission Unit (MTU) on a VMware vSphere Distributed Switch to a value larger than 9174 on a Pensando DPU If you have the vSphere Distributed Services Engine feature with a Pensando DPU enabled on your ESXi 8.0 system, you cannot set the Maximum Transmission Unit (MTU) on a vSphere Distributed Switch to a value larger than 9174. Workaround: None. You see link flapping on NICs that use the ntg3 driver of version 4.1.3 and later When two NICs that use the ntg3 driver of versions 4.1.3 and later are connected directly, not to a physical switch port, link flapping might occur. The issue does not occur on ntg3 drivers of versions earlier than 4.1.3 or the tg3 driver. This issue is not related to the occasional Energy Efficient Ethernet (EEE) link flapping on such NICs. The fix for the EEE issue is to use a ntg3 driver of version 4.1.7 or later, or disable EEE on physical switch ports. Workaround: Upgrade the ntg3 driver to version 4.1.8 and set the new module parameter noPhyStateSet to 1. The noPhyStateSet parameter defaults to 0 and is not required in most environments, except they face the issue. You cannot use Mellanox ConnectX-5, ConnectX-6 cards Model 1 Level 2 and Model 2 for Enhanced Network Stack (ENS) mode in vSphere 8.0 Due to hardware limitations, Model 1 Level 2, and Model 2 for Enhanced Network Stack (ENS) mode in vSphere 8.0 is not supported in ConnectX-5 and ConnectX-6 adapter cards. Workaround: Use Mellanox ConnectX-6 Lx and ConnectX-6 Dx or later cards that support ENS Model 1 Level 2, and Model 2A. Pensando DPUs do not support Link Layer Discovery Protocol (LLDP) on physical switch ports of ESXi hosts When you enable LLDP on an ESXi host with a DPU, the host cannot receive LLDP packets. Workaround: None. Storage Issues vSphere Storage vMotion operations might fail in a vSAN environment due to an unauthenticated session of the Network File Copy (NFC) manager Migrations to a vSAN datastore by using vSphere Storage vMotion of virtual machines that have at least one snapshot and more than one virtual disk with different storage policy might fail. The issue occurs due to an unauthenticated session of the NFC manager because the Simple Object Access Protocol (SOAP) body exceeds the allowed size. Workaround: First migrate the VM home namespace and just one of the virtual disks. After the operation completes, perform a disk only migration of the remaining 2 disks. vCenter Server and vSphere Client Issues PR 3667115: When editing vSphere Namespace CPU limits in the vSphere Client, values higher than 1000 GHz are incorrectly handled If you set a CPU limit on a vSphere Namespace higher than 1000 GHz, the vSphere Client might fall back to the default unit (MHz) instead of the respective unit in Terahertz (THz). For example, if you set a CPU limit of 1500 GHz, you should see the metric as 1.5 THz, but in the Resource Limits modal, you see a value of 1.5 with the unit selection box appearing empty or unselected. If you save the setting in this state, the system defaults to MHz, effectively slashing the 1500 GHz (1.5 THz) limit down to just 1.5 MHz. This issue is resolved in this release. You cannot hide or show plug-ins with 5-part version numbers in the vSphere Client In the vSphere Client, you cannot hide or show plug-ins registered with a 5-part version number, such as 9.0.0.0.12345, due to an issue with the serialization of 5-part package versions. Workaround: None. Instead of hiding or showing a plug-in with a 5-part version number in the vSphere Client, you can unregister and re-register the plug-in to achieve a similar result. PR 3667116: In the vSphere Client, very large SCSI vSphere Virtual Volumes datastores might display incorrect capacity and free space values When a SCSI vSphere Virtual Volumes datastore exceeds several exabytes, the vSphere Client fails to format the numerical value because it exceeds the maximum unit type defined in the formatting service. As a result, you see such capacity values as undefined. For example, 8 undefined free or 8 undefined capacity. The CLI and the Managed Object Browser (MOB) report the correct values. This issue is resolved in this release. The fix updates the storage unit service of the vSphere Client to handle and scale correctly extremely large capacity values to the maximum supported units. You cannot upload logs packages to a VMware service request by using the vSphere Client You cannot upload logs packages to a VMware service request by navigating in the vSphere Client to Administration > Support > Upload File to Service Request. Instead, you see a link to a KB article that provides steps to upload log bundles in the Broadcom Support Portal. This is expected. Workaround: Follow the steps in Uploading files to cases on the Broadcom Support Portal. A rare race in the vCenter automated space_cleanup utility when file-based backup is configured with an NFS volume might cause high memory usage vCenter 8.0 Update 3h has an automated space cleanup utility which is scheduled to run everyday at midnight to clean up old logs. In rare situations, due to a race condition, this scheduled cleanup task might conflict with the file-based backup and restore configured with an NFS mount point. As a result, you see high memory utilization from the space_utility process, which might consume most memory on the vCenter. Instance. Workaround: See KB 422390. When you move a standalone ESXi host back to a cluster that you manage with vSphere Lifecycle Manager images, you might see an error in the vSphere Client If you move out an ESXi host from a cluster that you manage with vSphere Lifecycle Manager images, it becomes a standalone host that is connected to a vCenter Server instance but is not part of any cluster. If you move such a host back to a cluster, in the Updates tab of the vSphere Client you might see an error such as The host [IP] is not a vLCM managed standalone host. This message does not indicate a functional issue. Workaround: Refresh the vSphere Client session or change the tab and return to the Updates tab. You see the same license product name displayed multiple times in the vSphere Client Starting with vSphere 8.0 Update 2b, you can apply a single Solution License to the components of VMware vSphere Foundation and VMware Cloud Foundation. In different screens in the vSphere Client, you might see the license product name multiplied by the number of components for which you use the license. For example, if you use a vSphere 8 Enterprise Plus for VMware Cloud Foundation license for 3 components, such as ESXi, vCenter, and vSphere with Tanzu, you see the name listed 3 times. Workaround: None An external gateway firewall might block vSphere Pod traffic to clusterIPs When you deploy Supervisor Services on vSphere Pods with Supervisors configured with the VDS stack, traffic from the vSphere Pod to ClusterIPs goes through the external gateway and a custom firewall can block it. Workaround: For more information, see vSphere Pod Traffic to ClusterIP Time-outs. A scheduled task fails and doesn't schedule further runs With vSphere 8.0 Update 2, if a vCenter user is unauthorized or unauthenticated, all scheduled tasks they own fail and cannot be scheduled until the user privileges are restored or a different vSphere user takes over the scheduled tasks. In the vSphere Client, you see messages for failed tasks and reasons for the failure. Workaround: Any vSphere user with sufficient privileges to edit scheduled tasks, including the current task owner with restored privileges, can click Edit and submit the scheduled task, without actually changing the scheduled task. For more information, see Scheduling vSphere Tasks. Virtual Machine Management Issues The vpxd agent might fail after expanding the disk size of a virtual machine with a NVMe controller in a vCenter 8.0 Update 3 mixed environment If you have ESXi hosts of version 8.0 Update 1 and earlier in your vCenter 8.0 Update 3 system, expanding the disk of a VM with a NVMe controller might cause the vpxd service to fail with core.vpxd-worker coredump. Workaround: Upgrade your ESXi hosts of version 8.0 Update 1 and earlier to 8.0 Update 3. Alternatively, use the VMware Host Client to extend the disk size from Edit settings of the VM. vSphere Lifecycle Manager Issues In the vSphere Client, you see a different count of components in a vSphere Lifecycle Manager image When you prepare a vSphere Lifecycle Manager image for a cluster or standalone ESXi host, and manually add or remove components, you might see a different count of the components in Updates > Hosts > Image > Components and in the list of components when you click Show details. The discrepancy occurs when the vSphere Lifecycle Manager considers not to use some of the additional components, for example if a driver is being deprecated, or if you remove a component, such as VMware Tools or Host Client. Workaround: None. You can safely ignore the difference in the count, because it does not impact the actual list of components that vSphere Lifecycle Manager uses for the image installation. You cannot edit the VMware vSphere Lifecycle Manager Update Download scheduled task In the vSphere Client, when you navigate to a vCenter Server instance and select Scheduled Tasks under the Configure tab, if you select the VMware vSphere Lifecycle Manager Update Download task and click Edit, you cannot modify the existing settings. Workaround: You can edit the VMware vSphere Lifecycle Manager Update Download task by following the steps in the topic Configure the vSphere Lifecycle Manager Automatic Download Task. Manually applied security advanced options on a vCenter system might not persist across vSphere Lifecycle Manager operations Some of all manually applied security advanced options on a vCenter system might not persist across vSphere Lifecycle Manager operations, such as upgrade, update, backup, or restore. Workaround: Re-apply the manual settings after the vSphere Lifecycle Manager task completes. If a parallel remediation task fails, you do not see the correct number of ESXi hosts that passed or skipped the operation With vSphere 8.0, you can enable vSphere Lifecycle Manager to remediate all hosts that are in maintenance mode in parallel instead of in sequence. However, if a parallel remediation task fails, in the vSphere Client you might not see the correct number of hosts that passed, failed, or skipped the operation, or even not see such counts at all. The issue does not affect the vSphere Lifecycle Manager functionality, but only the reporting in the vSphere Client. Workaround: None. A remediation task by using vSphere Lifecycle Manager might intermittently fail on ESXi hosts with DPUs When you start a vSphere Lifecycle Manager remediation on an ESXi hosts with DPUs, the host upgrades and reboots as expected, but after the reboot, before completing the remediation task, you might see an error such as: A general system error occurred: After host … remediation completed, compliance check reported host as 'non-compliant'. The image on the host does not match the image set for the cluster. Retry the cluster remediation operation. This is a rare issue, caused by an intermittent timeout of the post-remediation scan on the DPU. Workaround: Reboot the ESXi host and re-run the vSphere Lifecycle Manager compliance check operation, which includes the post-remediation scan. VMware Host Client Issues VMware Host Client might display incorrect descriptions for severity event states When you look in the VMware Host Client to see the descriptions of the severity event states of an ESXi host, they might differ from the descriptions you see by using Intelligent Platform Management Interface (IPMI) or Lenovo XClarity Controller (XCC). For example, in the VMware Host Client, the description of the severity event state for the PSU Sensors might be Transition to Non-critical from OK, while in the XCC and IPMI, the description is Transition to OK. Workaround: Verify the descriptions for severity event states by using the ESXCLI command esxcli hardware ipmi sdr list and Lenovo XCC. Security Features Issues If you use an RSA key size smaller than 2048 bits, RSA signature generation fails Starting from vSphere 8.0, ESXi uses the OpenSSL 3.0 FIPS provider. As part of the FIPS 186-4 requirement, the RSA key size must be at least 2048 bits for any signature generation, and signature generation with SHA1 is not supported. Workaround: Use RSA key size larger than 2048.
Original source - Jul 13, 2026
- Date parsed from source:Jul 13, 2026
- First seen by Releasebot:Nov 25, 2026
VMware vCenter Server by Broadcom
VMware vCenter 9.1.0.0200 Release Notes
VMware vCenter Server releases version 9.1.0.0200 with security enhancements and removes RVC from the restricted Appliance Shell, while retaining it in the standard BASH shell. The update also documents upgrade and backup issues with workarounds.
Introduction VMware vCenter 9.1.0.0200 | 13 JUL 2026 | Build 25573614 Check for additions and updates to these release notes. What's New This release contains various security enhancements. For vSphere Supervisor updates, see the vSphere Supervisor Release Notes. Product Support Notes Ruby vSphere Console (RVC) is no longer available in the Appliance Shell: With vCenter 9.1.0.0200, the interactive CLI for managing and monitoring vCenter environments especially for vSAN operations, RVC, is no longer available in the the restricted Appliance Shell, used for system commands and API tasks. RVC is deprecated and will be removed in a future vCenter release. You can still use RVC in the standard BASH shell. Build Details VMware vCenter 9.1.0.0200 Build Details Download Filename: VMware-vCenter-Server-Appliance-9.1.0.0200.25573614-patch-FP.iso Build: 25573614 Download Size: 8625.2 MB SHA256 checksum: 17bda708f1e58baf5c127f4f4caf31fe4d17b7d43ec8ad84bd89ef9bafe06e9b Applying the Patch Log in to the Broadcom Support Portal to download this patch, depending on your entitlement. For download instructions, see Download Broadcom products and software. For more information on using the vCenter shells, see Broadcom knowledge base article 2100508. For VCF environments, you apply this patch by using VCF Operations. See Upgrade or Patch an Individual VCF Component. For VMware vSphere Foundation environments, see Upgrading the vCenter Appliance. Known Issues A reset of the vSphere Lifecycle Manager database might cause data loss in the Supervisor If the vSphere Lifecycle Manager database in your environment is reset before upgrading vCenter from versions 8.0 Update 3 and later or 9.0.x to 9.1.0 or 9.1.1, the upgrade might cause data loss in the Supervisor. To avoid data loss, before a vCenter upgrade, you must first check your environment and take mitigation steps, if necessary. Workaround: See Broadcom knowledge base article 455737 for instructions how to check if your environment is affected and for mitigation steps. vCenter backup taken in Ehanced Linked Mode (ELM) cannot be restored after breaking ELM When a vCenter is in ELM, its Single Sign-On (SSO) domain maintains replication agreements with all partner vCenters. Backups taken in ELM environments capture such replication agreements. After breaking ELM, linked vCenter instances are removed from the topology, but the restored backup tries to re-establish SSO sync with them. As a result, the backup fails to restore with a message such as Error Failed to synchronize SSO data with partners. Workaround: After breaking ELM, take new backups to use for vCenter restore. During vCenter Reduced Downtime Upgrade (RDU), you see a warning that does not correctly display the version of VCF Operations and the target vCenter version During RDU from VCF version 9.0.x to 9.1, in the vSphere Client, you might see a precheck warning such as Registered VCF Ops's version '%(0)s' is lower than the target vCenter's '%(1)s, in which versions are not correctly displayed. Workaround: Ensure that VCF Operations is upgraded before vCenter to a version matching the new desired vCenter version, for example 9.1. You can ignore the error message.
Original source - Jun 5, 2026
- Date parsed from source:Jun 5, 2026
- First seen by Releasebot:Nov 25, 2026
VMware vCenter Server by Broadcom
VMware vCenter 9.1.0.0100 Release Notes
VMware vCenter Server releases version 9.1.0.0100 with security enhancements, along with upgrade guidance and a warning about possible Supervisor data loss after a vSphere Lifecycle Manager database reset.
VMware vCenter 9.1.0.0100 | 05 JUN 2026| Build 25417926 Check for additions and updates to these release notes. What's New This release contains various security enhancements. Build Details VMware vCenter 9.1.0.0100 Build Details Download Filename: VMware-vCenter-Server-Appliance-9.1.0.0100.25417926-patch-FP.iso Build: 25417926 Download Size: 8628.3 MB SHA256 checksum: 962b6a6442bee9ae5d0988ca2b1ef9b1c7cba5aeb2c8fe9a69df696a44409a3f Applying the Patch Log in to the Broadcom Support Portal to download this patch, depending on your entitlement. For download instructions, see Download Broadcom products and software. For more information on using the vCenter shells, see Broadcom knowledge base article 2100508. For VCF environments, you apply this patch by using VCF Operations. See Upgrade or Patch an Individual VCF Component. For VMware vSphere Foundation environments, see Upgrading the vCenter Appliance. Known Issues A reset of the vSphere Lifecycle Manager database might cause data loss in the Supervisor If the vSphere Lifecycle Manager database in your environment is reset before upgrading vCenter from versions 8.0 Update 3 and later or 9.0.x to 9.1.0 or 9.1.1, the upgrade might cause data loss in the Supervisor. To avoid data loss, before a vCenter upgrade, you must first check your environment and take mitigation steps, if necessary. Workaround: See Broadcom knowledge base article 455737 for instructions how to check if your environment is affected and for mitigation steps.
Original source - May 27, 2026
- Date parsed from source:May 27, 2026
- First seen by Releasebot:Nov 25, 2026
VMware vCenter Server by Broadcom
VMware vCenter 8.0 Update 3j Release Notes
VMware vCenter Server releases Update 3j with automatic renewal of expiring VMCA certificates, clearer upgrade prechecks for directory replication issues, and fixes across vSphere operations, migrations, storage, and lifecycle management. The update also improves reliability and visibility for administrators.
Introduction VMware vCenter 8.0 Update 3j | 27 MAY 2026 | ISO Build 25413364 Check for additions and updates to these release notes. What's New This release contains bugfixes as listed in the Resolved Issues section. For vSphere Supervisor updates, see the vSphere Supervisor 8.0 Release Notes. For Photon OS updates, see VMware vCenter Server Appliance Photon OS Security Patches. Automatic renewal of VMware Certificate Authority (VMCA) root certificate: To avoid any issues due to expired VMCA root certificate and to minimize the downtime for their renewal, in vCenter 8.0 Update 3j, the VMCA root certificate and the solution user certificates are automatically renewed if they are set to expire in less than 2 years. The automatic certificate renewal is triggered as part of the vCenter upgrade process. After the vCenter system is successfully upgraded, the VMCA root certificate is valid for 10 years. Upgrade precheck messages for the VMware Directory Service (VMDIR): A precheck at stage 2 of a vCenter upgrade reports issues related to replications in VMDIR, the vCenter LDAP repository that contains user identities, groups, and configuration data. If the prechecks fails, it could be as a result of a replication failure with other vCenter instances or due to the presence of stale nodes, but the messages in the vSphere Client do not provide information of which node is causing the issue or guidance to fix the issue. This enhancement adds links to knowledge base articles with corrective actions and lists the affected vCenter instances as part of the precheck messages in case of a replication failure. Upgrade Notes Upgrade from vCenter 8.0 Update 3j to vCenter 9.1.0 or any EP based on 9.1.0 is not supported. Forward upgrade path to 9.x will be available in the future 9.x release. Build Details VMware vCenter 8.0 Update 3j Download Filename VMware-vCenter-Server-Appliance-8.0.3.00900-25413364-patch-FP.iso Build 25413364 Download Size 8532.1 MB sha256checksum 21f1ab40fd8ba58cc63996d685ee4a4c95f4e176735b632e9cf0ffc24defacf9 PRs fixed 3671446, 3671365, 3681930, 3642455, 3671216, 3666953, 3666947, 3666958, 3666938, 3652938, 3669261, 3660320, 3641149, 3636196, 3681400, 3661385, 3661145, 3660320, 3644196, 3643568, 3654023, 3637874, 3679759, 3643715 CVEs N/A Download and Installation Log in to the Broadcom Support Portal to download this patch. See these KBs for details on the authenticated online and offline download: 390121, 390098, and 389276. For more information on using the vCenter Server shells, see VMware knowledge base article 2100508. For more information on patching vCenter Server, see Patching and Updating vCenter Server 8.0 Deployments. For more information on staging patches, see Upgrading the vCenter Server Appliance. Resolved Issues Miscellaneous Issues PR 3681930: You cannot clone a virtual machine with Raw Device Mappings (RDM) disk to a VM with thin flat disk When you clone a VM with an RDM disk and select the thin provisioning option, the resulting disk is always converted to a thick flat disk. This issue is resolved in this release. PR 3642455: Distributed Power Management (DPM) operations such as enterStandbyMode and exitStandbyMode might fail due to a limitation in the IPMI library A limitation in the Intelligent Platform Management Interface (IPMI) library to monitor up to 1024 open socket connections might cause DPM operations such as enterStandbyMode and exitStandbyMode to fail with an error IPMILIB - too many open connections. This issue is resolved in this release. vSphere Client and vCenter Issues PR 3671216: Enhanced Linked Mode (ELM) topology connectivity fails without a notification Since no automated monitoring exists to detect when a vCenter node in an ELM topology becomes unreachable, the replication topology might be in a disconnected state and you do not see a notification. This issue is resolved in this release. The fix adds a connectivity check that runs automatically every 8 hours and triggers an alarm to help administrators take action if any ELM nodes shut down or not cleanly decommissioned from the federation. PR 3666953: When you use the cmsso-util unregister command to remove a node, Enhanced Linked Mode (ELM) topology might disconnect When you use the cmsso-util unregister command to remove a vCenter instance from an ELM topology, replication topologies are not actively validated prior to or during the decommissioning of the vCenter node, potentially leading to unresolved network isolation issues. As a result, data might not be replicated in all nodes. This issue is resolved in this release. The fix enhances the cmsso-util unregister command pre-check functionality to validate that the ELM topology remains connected after a node is removed. PR 3666947: You can accidentally remove a node from Enhanced Linked Mode (ELM) topology by running the cmsso-util unregister command on the same vCenter instance When you run the cmsso-util unregister command from a vCenter instance, you might accidentally unregister that same vCenter instead of another node in the topology. This issue is resolved in this release. The fix adds a validation that the cmsso-util unregister command does not target the vCenter instance from which it is run. PR 3671446: You do not see messages for failed iSCSI login authentication in vCenter Events iSCSI login authentication issues are not correctly tracked in vCenter and under Events you do not see failure messages. This issue is resolved in this release. The fix adds appropriate messages with an error code in vCenter logs. PR 3671365: You do not see messages for failed iSCSI connectivity to the target in vCenter Events Issues with the iSCSI connectivity to the target, due to network-related issues for example, are not correctly tracked in vCenter and in case of network connectivity errors, you do not see failure messages under Events. As a result, iSCSI-related issues such as NOP-OUT packet timeout might go unnoticed. This issue is resolved in this release. The fix adds appropriate messages in vCenter logs. PR 3666958: Some vCenter services or operations might fail due to machine account password mismatch If the machine account password stored in the VMware Directory Service (VMDIR) database does not match the password used by a given vCenter service, such services fail to start or some vCenter operations fail, but you do not see a notification or informative error message. This issue is resolved in this release. The fix adds the error message Machine Account password mismatch. Refer to KB 316608, providing a vCenter alarm on the condition and steps for remediation. PR 3666938: Running the cmsso-util unregister command for a vCenter that is not powered off causes an inconsistent state of the vCenter If you do not power off or shut down a vCenter instance before running the cmsso-util unregister command, as required, the operation fails and the vCenter instance is in an inconsistent state. This issue is resolved in this release. The fix adds a pre-check to make sure the vCenter being unregistered is powered off before triggering the cmsso-util unregister command for it from another linked vCenter instance. PR 3652938: vCenter fails to start post upgrade when VMware Directory Service (VMDIR) is in ACL MODE: Legacy and the Source VC is configured with ADFS If VMDIR is in ACL MODE: Legacy and Active Directory Federation Services (ADFS) is configured on the source machine, vCenter fails to start after an upgrade to version 8.0 Update 3h and later. This issue is resolved in this release. PR 3669261: When using Advanced Cross vCenter vMotion workflow, multiple powered-off virtual machines are registered to a single ESXi host In vSphere 8.0 Update 3 and earlier, when using Advanced Cross vCenter vMotion, vCenter automatically selects the first available ESXi host in the destination cluster for cold cross-vCenter migrations. As a result, multiple powered-off virtual machines are registered to a single host instead of being distributed across the cluster. This issue is resolved in this release. The fix ensures that for targets of version vCenter 8.0 and later, host selection is handled by the placement engine (DRS), while for targets of version earlier than vCenter 8.0, a host is randomly selected to prevent hotspots. PR 3660320: You do not see the Custom Attributes card under the Summary tab in the Resource Pool page In the vSphere Client, when you navigate to Resource Pools > Summary, you do not see the Custom Attributes' card. This issue is resolved in this release. PR 3641149: Newer Guest OS on older VM hardware versions might cause VMware Tools or hardware scans and upgrades to fail If a newer Guest OS, such as Windows 2019, is installed on a VM with virtual hardware version earlier than 17, scheduling or scanning for VMware Tools upgrade or VM Hardware Compatibility fails. In the vSphere Client, you see the error Operation is not supported on the object. This issue is resolved in this release. PR 3636196: After an update, the SNMP service might not be active The SNMP service might be inactive after an update by using Remote Downtime Upgrade or a regular update between versions of vCenter 8.x. and you need to activate the service manually. The issue does not occur in upgrades between major versions of vCenter, such as 8.x and 9.x. This issue is resolved in this release. PR 3681400: During Reduced Downtime Upgrade (RDU) prechecks you see a warning for RPMs that are not part of the vCenter installation When running an RDU precheck, in the vSphere Client you might see a warning such as Found the following RPMs that are not part of the vCenter Server installation: [oniguruma, vsphere-ui-config, VMware-spherelet_1_29]. This issue is resolved in this release. The fix updates the RPM list. PR 3661385: If the ESXi host selected to create an NFC session during a File Manager download is entering maintenance mode, backup tasks might fail During a vCenter backup, if you are using File Manager download, while downloading VMDKs from a datastore browser, an NFC session is created with the selected ESXi host. If the host is entering maintenance mode, the NFC session fails and as a result, the backup fails. This issue is resolved in this release. The fix prevents the selection of ESX hosts which are entering or exiting maintenance mode when creating an NFC session to download VMDKs using File Manager. PR 3661145: A vApp does not retain changes to some settings after a restart of vCenter or the VPXD service Some settings of vApps such as the start order and the IP allocation are not updated in the vCenter database when they are changed. As a result, they might revert to previous values after a reboot of vCenter or a restart of the VPXD service. This issue is resolved in this release. PR 3660320: You do not see the Custom Attributes card under the Summary tab in the Resource Pool page In the vSphere Client, when you navigate to Resource Pools > Summary, you do not see the Custom Attributes card. This issue is resolved in this release. PR 3644196: vCenter tagging API might allow attaching multiple tags to the same category even when cardinality is set to "SINGLE" For vCenter 8.0 Update 3h and earlier, due to a cardinality validation issue, you can attach multiple tags to the same category on a virtual machine by using the attach_multiple_tags_to_object tagging API even when cardinality is set to SINGLE. This issue is resolved in this release. PR 3643568: The VPXD service might fail when virtual machines are restored by using the Commvault backup solution During the update of the properties of a VM that is restored by using the commonvault API, the VPXD service might fail. This issue is resolved in this release. Upgrade Issues PR 3643715: VCF 5.2.x deployment fails with a checksum mismatch error when a VMware Tools async release VIB is installed on the ESXi host used for image extraction When for imaging other ESXi hosts you extract an image from an ESXi host of version 8.0 Update 3 or later that has an async VMware Tools component installed, which uses Python 3.11, the VMware Tools locker VIB payload might use a tar header format that differs from the one used by Python versions 3.8.17 and earlier. An inconsistency in the encoding of the devmajor and devminor fields in the tar header might cause the recalculated checksum to differ from the checksum stored in the original async VMware Tools VIB. As a result, you see a VibChecksumError or VibPayloadDigestError and the image extraction step during VCF deployment fails. This issue is resolved in this release. PR 3654023: During an upgrade, you see a precheck warning when /storage/archive utilization exceeds 90% During an upgrade, in the vSphere Client you might see a warning such as In the vCenter Server Appliance, the disk /storage/archive has a total size of 52 GB, of which 0 GB is free. Such precheck warnings trigger when /storage/archive utilization exceeds 90%, but since high utilization is expected, the warning is a false positive. This issue is resolved in this release. The fix removes precheck warnings when /storage/archive utilization exceeds 90%. vSAN Issues PR 3637874: You cannot see data for vSAN virtual objects in the vSphere Client In the vSphere Client, when you navigate from a cluster to Monitor > vSAN > Virtual Objects, a preview loads for a moment but then you see the error: Unable to extract requested data. Check vSphere Client logs for details. The issue occurs specifically when a VM snapshot without associated devices exists in the cluster. This issue is resolved in this release. vSphere Lifecycle Manager Issues PR 3679759: Syncing the vSphere Lifecycle Manager depot fails due to invalid tokens Using the /dl.broadcom.com/ URL in the vSphere Lifecycle Manager depot requires entitlement tokens and if your environment has invalid tokens for some reason, syncing the vSphere Lifecycle Manager depot fails. This issue is resolved in this release. The fix adds alerts for issues related to entitlement tokens. If your token is expired or invalid, generate new entitlement token and reconfigure the vSphere Lifecycle Manager depot. PR 3679759: Syncing the vSphere Lifecycle Manager depot fails due to deprecated URLs in the vSphere Lifecycle Manager download sources In the vSphere Lifecycle Manager download sources, you might see the deprecated /hostupdate.vmware.com/ URL along with the /dl.broadcom.com/ URL, which requires entitlement tokens. As a result, syncing the vSphere Lifecycle Manager depot fails. This issue is resolved in this release. The fix removes all deprecated URLs. Known Issues vCenter and vSphere Client Issues You cannot hide or show plug-ins with 5-part version numbers in the vSphere Client In the vSphere Client, you cannot hide or show plug-ins registered with a 5-part version number, such as 9.0.0.0.12345, due to an issue with the serialization of 5-part package versions. Workaround: None. Instead of hiding or showing a plug-in with a 5-part version number in the vSphere Client, you can unregister and re-register the plug-in to achieve a similar result. Known Issues from Previous Releases Installation, Upgrade, and Migration Issues If you do not open port 9087 in your firewall between ESXi hosts and vCenter, compliance checks and vSphere HA might fail after vCenter update to 8.0 Update 3 Starting from 8.0 Update 3, the vSphere Lifecycle Manager downloads updates for ESXi hosts by a HTTPS connection to the vCenter instance on port 9087. If you do not open port 9087 in your firewall between ESXi hosts and vCenter, you might see compliance check errors. For example, in the lifecycle.log you see messages such as: <Timestamp> In(14) lifecycle[2112988]: Downloader:373 Opening https://<VC-FQDN>:9087/vum/repository/hostupdate/__micro-depot__vendor-DEL__DEL-ESXi-8.0-Addon-cumulative_metadata__index__.xml for download <Timestamp> Wa(12) lifecycle[2112988]: Downloader:210 Download failed: <urlopen error timed out>, 9 retry left... In addition, vSphere HA might fail to start. Workaround: Open port 9087 in your firewall between ESXi hosts and vCenter by using the TCP protocol. In a mixed vSphere 7.x and 8.x environment with vSphere DRS, an incompatible virtual machine might prevent an ESXi host to enter maintenance mode In a mixed vSphere 7.x and 8.x environment with DRS, a VM of 7.x version that is not compatible with ESXi 8.0 Update 1 and later might prevent an ESXi 8.0 Update 1 host to enter maintenance mode. The issue is specific for virtual machines with VMDK on a vSphere Virtual Volumes datastore. In the vSphere Client, you see an error such as Waiting for all VMs to be powered off or suspended or migrated. In a DRS cluster check the Faults page on the DRS tab for troubleshooting. Workaround: Power-off the incompatible virtual machine. vSphere Lifecycle Manager baseline check compliance fails on ESXi hosts of version 7.0 GA in a vCenter 8.0 Update 3 system Due to a limitation of the esxupdate memory resource pool on 7.0 GA ESXi hosts, a vSphere Lifecycle Manager baseline check compliance scan might fail on 7.0 GA ESXi host in a vCenter 8.0 Update 3 system with error such as The host returns esxupdate error codes: -1. The host esxupdate.log contains an error such as: <Timestamp> esxupdate: <PID>: esxupdate: ERROR: vmware.runcommand.RunCommandError: Error running command '['/sbin/smbiosDump']': [Errno 12] Cannot allocate memory The vmkernel.log contains error such as: <Timestamp> cpu0:<PID>)Admission failure in path: host/vim/vmvisor/esxupdate/python.<PID>:python.<PID>:uw.<PID> This issue is specific for 7.0 GA ESXi hosts, as esxupdate memory allocation is increased in 7.0 Update 1 and later. Workaround: Use an ISO upgrade baseline to upgrade the 7.0 GA ESXi hosts to a 8.x version or revert the vCenter system back to version 7.0 and upgrade the hosts to a version of 7.0 Update 1 and later. You see an error Failed to get ceip status in the Virtual Appliance Management Interface (VAMI) during update to vCenter Server 8.0 Update 1 During an update, vCenter stops and restarts the VMDir service and within this interval, if you try to log in to the VAMI, you might see an error such as Failed to get ceip status. This is expected and does not indicate an actual issue with the vCenter system. Workaround: Wait for the VMDir service to restart and refresh the Virtual Appliance Management Interface. If you click NEXT before the progress bar reaches 100% in a vCenter Server Lifecycle Manager plug-in upgrade, the Server Lifecycle Manager service fails In the Upgrade Plug-in step of the vCenter Server Lifecycle Manager plug-in upgrade wizard, if you click NEXT before the progress bar reaches 100%, the Server Lifecycle Manager service fails. Workaround: Wait for the progress bar to reach 100% before you click NEXT. vCenter upgrade or update to 8.0 Update 2a or later fails during precheck with the error "VMCA root certificate validation failed" If your vCenter system has a legacy VMCA root certificate dating back to version 5.x which does not have the Subject Key Identifier (SKID) extension, upgrades and updates to vCenter 8.0 Update 2 and later fail because the OpenSSL version 3.0 in 8.0 Update 2 is not compatible with legacy root certificates. vCenter Server 8.0 Update 2a adds a precheck to detect this issue and shows the error message VMCA root certificate validation failed if the source vCenter has VMCA root certificate without SKID. Workaround: Regenerate a VMCA root certificate by following the steps in VMware knowledge base article 94840. You see a "vc.health.error.dbjob3" warning after a vCenter upgrade In the vSphere Client or the in Virtual Appliance Management Interface, you might see the warning vc.health.error.dbjob3 after a vCenter upgrade although the vCenter overall health status is green. This issue does not affect vCenter operations, it can only affect historical statistics when some data does not roll up for more than 72 hours. Workaround: See Delete old tasks, events and statistics data in vCenter Server 5.x, 6.x, 7.x and 8.x how to clear stats data, if not relevant anymore. Update to vCenter 8.0 Update 3 might fail with an error "Destination path '/storage/analytics/stage/...' already exists" Starting with vCenter 8.0 Update 3, the analytics service stores telemetry log files in a new directory. In rare cases, if previous update attempts had failed and reverted, when patching to vCenter 8.0 Update 3, the attempt to copy the telemetry log files to the new location might fail because these files already exist from a prior patching attempt. In the patchrunner.log file, you see an error such as Destination path '/storage/analytics/stage/XXXXXX_processed_logs' already exists. Workaround: Delete all files under /storage/log/vmware/analytics/stage, /storage/log/vmware/analytics/prod, /storage/analytics/stage, and /storage/analytics/prod, and retry the update. You see a security warning for the ESX Agent Manager configuration during the pre-check phase of a vCenter upgrade During the pre-check phase of a vCenter update or upgrade, in the vSphere Client and logs, you might see an error such as: Source ESX Agent Manager Configuration contains URLs that are not trusted by the System! Verify following URLs and their respective statuses and follow KB 93526. Workaround: For more information, see VMware knowledge base article 93526. Firmware compliance details are missing from a vSphere Lifecycle Manager image compliance report for an ESXi standalone host Firmware compliance details might be missing from a vSphere Lifecycle Manager image compliance report for an ESXi standalone host in two cases: You run a compliance report against a standalone host managed with a vSphere Lifecycle Manager image from vSphere Client and then navigate away before the compliance report gets generated. You trigger a page refresh after the image compliance reports are generated. In such cases, even when you have the firmware package available in the Desired State, the firmware compliance section remains empty when you revisit or refresh the vSphere Client browsing session. If you use GET image compliance API, then firmware compliance details are missing from the response. Workaround: Invoke the image compliance scan for a standalone host managed with a vSphere Lifecycle Manager image by using the vSphere Client and do not navigate away or refresh the browser. For API, use the Check image compliance API for fetching the firmware details as apposed to GET image compliance. If you apply a host profile using a software FCoE configuration to an ESXi 8.0 host, the operation fails with a validation error Starting from vSphere 7.0, software FCoE is deprecated, and in vSphere 8.0 software FCoE profiles are not supported. If you try to apply a host profile from an earlier version to an ESXi 8.0 host, for example to edit the host customization, the operation fails. In the vSphere Client, you see an error such as Host Customizations validation error. Workaround: Disable the Software FCoE Configuration subprofile in the host profile. URL-based patching or file-based backup of vCenter 8.0 Update 2 might fail due to OpenSSL noncompliance to Federal Information Processing Standards (FIPS) With vCenter 8.0 Update 2, OpenSSL works only with Diffie-Hellman parameters compliant to NIST SP 800-56A and FIPS 140-2. For URL-based patching or file-based backup of vCenter 8.0 Update 2 systems, FTPS servers in your environment must support the following ciphers: DHE-RSA-AES256-SHA | TLS_DHE_RSA_WITH_AES_256_CBC_SHA | 39 DHE-DSS-AES256-SHA | TLS_DHE_DSS_WITH_AES_256_CBC_SHA | 38 AES256-SHA | TLS_RSA_WITH_AES_256_CBC_SHA | 35 EDH-RSA-DES-CBC3-SHA | TLS_DHE_RSA_WITH_3DES_EDE_CBC_SHA | 16 EDH-DSS-DES-CBC3-SHA | TLS_DHE_DSS_WITH_3DES_EDE_CBC_SHA | 13 DES-CBC3-SHA | TLS_RSA_WITH_3DES_EDE_CBC_SHA | 0A DHE-RSA-AES128-SHA | TLS_DHE_RSA_WITH_AES_128_CBC_SHA | 33 DHE-DSS-AES128-SHA | TLS_DHE_DSS_WITH_AES_128_CBC_SHA | 32 AES128-SHA | TLS_RSA_WITH_AES_128_CBC_SHA | 2F Workaround: Make sure your file servers are FIPS compliant. VMNICs might be down after an upgrade to ESXi 8.0 If the peer physical switch of a VMNIC does not support Media Auto Detect, or Media Auto Detect is disabled, and the VMNIC link is set down and then up, the link remains down after upgrade to or installation of ESXi 8.0. Workaround: Use either of these 2 options: Enable the option media-auto-detect in the BIOS settings by navigating to System Setup Main Menu, usually by pressing F2 or opening a virtual console, and then Device Settings > <specific broadcom NIC> > Device Configuration Menu > Media Auto Detect. Reboot the host. Alternatively, use an ESXCLI command similar to: esxcli network nic set -S <your speed> -D full -n <your nic>. With this option, you also set a fixed speed to the link, and it does not require a reboot. After upgrade to ESXi 8.0, you might lose some nmlx5_core driver module settings due to obsolete parameters Some module parameters for the nmlx5_core driver, such as device_rss, drss, and rss, are deprecated in ESXi 8.0 and any custom values, different from the default values, are not kept after an upgrade to ESXi 8.0. Workaround: Replace the values of the device_rss, drss and rss parameters as follows: device_rss: Use the DRSS parameter. drss: Use the DRSS parameter. rss: Use the RSS parameter. Miscellaneous Issues In a vCenter Server system with DPUs, if IPv6 is disabled, you cannot manage DPUs Although the vSphere Client allows the operation, if you disable IPv6 on an ESXi host with DPUs, you cannot use the DPUs, because the internal communication between the host and the devices depends on IPv6. The issue affects only ESXi hosts with DPUs. Workaround: Make sure IPv6 is enabled on ESXi hosts with DPUs. You might see 10 min delay in rebooting an ESXi host on HPE server with pre-installed Pensando DPU In rare cases, HPE servers with pre-installed Pensando DPU might take more than 10 minutes to reboot in case of a failure of the DPU. As a result, ESXi hosts might fail with a purple diagnostic screen and the default wait time is 10 minutes. Workaround: None. If you have an USB interface enabled in a remote management application that you use to install ESXi 8.0, you see an additional standard switch vSwitchBMC with uplink vusb0 Starting with vSphere 8.0, in both Integrated Dell Remote Access Controller (iDRAC) and HP Integrated Lights Out (ILO), when you have an USB interface enabled, vUSB or vNIC respectively, an additional standard switch vSwitchBMC with uplink vusb0 gets created on the ESXi host. This is expected, in view of the introduction of data processing units (DPUs) on some servers but might cause the VMware Cloud Foundation Bring-Up process to fail. Workaround: Before vSphere 8.0 installation, disable the USB interface in the remote management application that you use by following vendor documentation. After vSphere 8.0 installation, use the ESXCLI command esxcfg-advcfg -s 0 /Net/BMCNetworkEnable to prevent the creation of a virtual switch vSwitchBMC and associated portgroups on the next reboot of host. See this script as an example: ~# esxcfg-advcfg -s 0 /Net/BMCNetworkEnable The value of BMCNetworkEnable is 0 and the service is disabled. ~# reboot On host reboot, no virtual switch, PortGroup and VMKNIC are created in the host related to remote management application network. If an NVIDIA BlueField DPU is in hardware offload mode disabled, virtual machines with configured SR-IOV virtual function cannot power on NVIDIA BlueField DPUs must be in hardware offload mode enabled to allow virtual machines with configured SR-IOV virtual function to power on and operate. Workaround: Always use the default hardware offload mode enabled for NVIDIA BlueField DPUs when you have VMs with configured SR-IOV virtual function connected to a virtual switch. ESXi hosts might become unresponsive, and you see a vpxa dump file due to a rare condition of insufficient file descriptors for the request queue on vpxa In rare cases, when requests to the vpxa service take long, for example waiting for access to a slow datastore, the request queue on vpxa might exceed the limit of file descriptors. As a result, ESXi hosts might briefly become unresponsive, and you see a vpxa-zdump.00* file in the /var/core directory. The vpxa logs contain the line Too many open files. Workaround: None. The vpxa service automatically restarts and corrects the issue. Networking Issues Overlapping hot-add and hot-remove operations for DirectPath I/O devices might fail With vSphere 8.0 Update 1, by using vSphere API you can add or remove a DirectPath I/O device without powering off VMs. However, if you run several operations at the same time, some of the overlapping tasks might fail. Workaround: Plan for 20 seconds processing time between each hot-add or hot-remove operation for DirectPath I/O devices. Hot adding and removing of DirectPath I/O devices is not automatically enabled on virtual machines With vSphere 8.0 Update 1, by using vSphere API you can add or remove a DirectPath I/O device without powering off VMs. When you enable the hotplug functionality that allows you to hot add and remove DirectPath I/O devices to a VM, if you use such a VM to create an OVF and deploy a new VM, the new VM might not have the hotplug functionality automatically enabled. Workaround: Enable the hotplug functionality as described in Hot-add and Hot-remove support for VMDirectPath I/O Devices. You cannot set the Maximum Transmission Unit (MTU) on a VMware vSphere Distributed Switch to a value larger than 9174 on a Pensando DPU If you have the vSphere Distributed Services Engine feature with a Pensando DPU enabled on your ESXi 8.0 system, you cannot set the Maximum Transmission Unit (MTU) on a vSphere Distributed Switch to a value larger than 9174. Workaround: None. You see link flapping on NICs that use the ntg3 driver of version 4.1.3 and later When two NICs that use the ntg3 driver of versions 4.1.3 and later are connected directly, not to a physical switch port, link flapping might occur. The issue does not occur on ntg3 drivers of versions earlier than 4.1.3 or the tg3 driver. This issue is not related to the occasional Energy Efficient Ethernet (EEE) link flapping on such NICs. The fix for the EEE issue is to use a ntg3 driver of version 4.1.7 or later, or disable EEE on physical switch ports. Workaround: Upgrade the ntg3 driver to version 4.1.8 and set the new module parameter noPhyStateSet to 1. The noPhyStateSet parameter defaults to 0 and is not required in most environments, except they face the issue. You cannot use Mellanox ConnectX-5, ConnectX-6 cards Model 1 Level 2 and Model 2 for Enhanced Network Stack (ENS) mode in vSphere 8.0 Due to hardware limitations, Model 1 Level 2, and Model 2 for Enhanced Network Stack (ENS) mode in vSphere 8.0 is not supported in ConnectX-5 and ConnectX-6 adapter cards. Workaround: Use Mellanox ConnectX-6 Lx and ConnectX-6 Dx or later cards that support ENS Model 1 Level 2, and Model 2A. Pensando DPUs do not support Link Layer Discovery Protocol (LLDP) on physical switch ports of ESXi hosts When you enable LLDP on an ESXi host with a DPU, the host cannot receive LLDP packets. Workaround: None. Storage Issues vSphere Storage vMotion operations might fail in a vSAN environment due to an unauthenticated session of the Network File Copy (NFC) manager Migrations to a vSAN datastore by using vSphere Storage vMotion of virtual machines that have at least one snapshot and more than one virtual disk with different storage policy might fail. The issue occurs due to an unauthenticated session of the NFC manager because the Simple Object Access Protocol (SOAP) body exceeds the allowed size. Workaround: First migrate the VM home namespace and just one of the virtual disks. After the operation completes, perform a disk only migration of the remaining 2 disks. vCenter Server and vSphere Client Issues PR 3667115: When editing vSphere Namespace CPU limits in the vSphere Client, values higher than 1000 GHz are incorrectly handled If you set a CPU limit on a vSphere Namespace higher than 1000 GHz, the vSphere Client might fall back to the default unit (MHz) instead of the respective unit in Terahertz (THz). For example, if you set a CPU limit of 1500 GHz, you should see the metric as 1.5 THz, but in the Resource Limits modal, you see a value of 1.5 with the unit selection box appearing empty or unselected. If you save the setting in this state, the system defaults to MHz, effectively slashing the 1500 GHz (1.5 THz) limit down to just 1.5 MHz. This issue is resolved in this release. PR 3667116: In the vSphere Client, very large SCSI vSphere Virtual Volumes datastores might display incorrect capacity and free space values When a SCSI vSphere Virtual Volumes datastore exceeds several exabytes, the vSphere Client fails to format the numerical value because it exceeds the maximum unit type defined in the formatting service. As a result, you see such capacity values as undefined. For example, 8 undefined free or 8 undefined capacity. The CLI and the Managed Object Browser (MOB) report the correct values. This issue is resolved in this release. The fix updates the storage unit service of the vSphere Client to handle and scale correctly extremely large capacity values to the maximum supported units. You cannot upload logs packages to a VMware service request by using the vSphere Client You cannot upload logs packages to a VMware service request by navigating in the vSphere Client to Administration > Support > Upload File to Service Request. Instead, you see a link to a KB article that provides steps to upload log bundles in the Broadcom Support Portal. This is expected. Workaround: Follow the steps in Uploading files to cases on the Broadcom Support Portal. A rare race in the vCenter automated space_cleanup utility when file-based backup is configured with an NFS volume might cause high memory usage vCenter 8.0 Update 3h has an automated space cleanup utility which is scheduled to run everyday at midnight to clean up old logs. In rare situations, due to a race condition, this scheduled cleanup task might conflict with the file-based backup and restore configured with an NFS mount point. As a result, you see high memory utilization from the space_utility process, which might consume most memory on the vCenter. Instance. Workaround: See KB 422390. When you move a standalone ESXi host back to a cluster that you manage with vSphere Lifecycle Manager images, you might see an error in the vSphere Client If you move out an ESXi host from a cluster that you manage with vSphere Lifecycle Manager images, it becomes a standalone host that is connected to a vCenter Server instance but is not part of any cluster. If you move such a host back to a cluster, in the Updates tab of the vSphere Client you might see an error such as The host [IP] is not a vLCM managed standalone host. This message does not indicate a functional issue. Workaround: Refresh the vSphere Client session or change the tab and return to the Updates tab. You see the same license product name displayed multiple times in the vSphere Client Starting with vSphere 8.0 Update 2b, you can apply a single Solution License to the components of VMware vSphere Foundation and VMware Cloud Foundation. In different screens in the vSphere Client, you might see the license product name multiplied by the number of components for which you use the license. For example, if you use a vSphere 8 Enterprise Plus for VMware Cloud Foundation license for 3 components, such as ESXi, vCenter, and vSphere with Tanzu, you see the name listed 3 times. Workaround: None An external gateway firewall might block vSphere Pod traffic to clusterIPs When you deploy Supervisor Services on vSphere Pods with Supervisors configured with the VDS stack, traffic from the vSphere Pod to ClusterIPs goes through the external gateway and a custom firewall can block it. Workaround: For more information, see vSphere Pod Traffic to ClusterIP Time-outs. A scheduled task fails and doesn't schedule further runs With vSphere 8.0 Update 2, if a vCenter user is unauthorized or unauthenticated, all scheduled tasks they own fail and cannot be scheduled until the user privileges are restored or a different vSphere user takes over the scheduled tasks. In the vSphere Client, you see messages for failed tasks and reasons for the failure. Workaround: Any vSphere user with sufficient privileges to edit scheduled tasks, including the current task owner with restored privileges, can click Edit and submit the scheduled task, without actually changing the scheduled task. For more information, see Scheduling vSphere Tasks. Virtual Machine Management Issues The vpxd agent might fail after expanding the disk size of a virtual machine with a NVMe controller in a vCenter 8.0 Update 3 mixed environment If you have ESXi hosts of version 8.0 Update 1 and earlier in your vCenter 8.0 Update 3 system, expanding the disk of a VM with a NVMe controller might cause the vpxd service to fail with core.vpxd-worker coredump. Workaround: Upgrade your ESXi hosts of version 8.0 Update 1 and earlier to 8.0 Update 3. Alternatively, use the VMware Host Client to extend the disk size from Edit settings of the VM. vSphere Lifecycle Manager Issues In the vSphere Client, you see a different count of components in a vSphere Lifecycle Manager image When you prepare a vSphere Lifecycle Manager image for a cluster or standalone ESXi host, and manually add or remove components, you might see a different count of the components in Updates > Hosts > Image > Components and in the list of components when you click Show details. The discrepancy occurs when the vSphere Lifecycle Manager considers not to use some of the additional components, for example if a driver is being deprecated, or if you remove a component, such as VMware Tools or Host Client. Workaround: None. You can safely ignore the difference in the count, because it does not impact the actual list of components that vSphere Lifecycle Manager uses for the image installation. You cannot edit the VMware vSphere Lifecycle Manager Update Download scheduled task In the vSphere Client, when you navigate to a vCenter Server instance and select Scheduled Tasks under the Configure tab, if you select the VMware vSphere Lifecycle Manager Update Download task and click Edit, you cannot modify the existing settings. Workaround: You can edit the VMware vSphere Lifecycle Manager Update Download task by following the steps in the topic Configure the vSphere Lifecycle Manager Automatic Download Task. Manually applied security advanced options on a vCenter system might not persist across vSphere Lifecycle Manager operations Some of all manually applied security advanced options on a vCenter system might not persist across vSphere Lifecycle Manager operations, such as upgrade, update, backup, or restore. Workaround: Re-apply the manual settings after the vSphere Lifecycle Manager task completes. If a parallel remediation task fails, you do not see the correct number of ESXi hosts that passed or skipped the operation With vSphere 8.0, you can enable vSphere Lifecycle Manager to remediate all hosts that are in maintenance mode in parallel instead of in sequence. However, if a parallel remediation task fails, in the vSphere Client you might not see the correct number of hosts that passed, failed, or skipped the operation, or even not see such counts at all. The issue does not affect the vSphere Lifecycle Manager functionality, but only the reporting in the vSphere Client. Workaround: None. A remediation task by using vSphere Lifecycle Manager might intermittently fail on ESXi hosts with DPUs When you start a vSphere Lifecycle Manager remediation on an ESXi hosts with DPUs, the host upgrades and reboots as expected, but after the reboot, before completing the remediation task, you might see an error such as: A general system error occurred: After host … remediation completed, compliance check reported host as 'non-compliant'. The image on the host does not match the image set for the cluster. Retry the cluster remediation operation. This is a rare issue, caused by an intermittent timeout of the post-remediation scan on the DPU. Workaround: Reboot the ESXi host and re-run the vSphere Lifecycle Manager compliance check operation, which includes the post-remediation scan. VMware Host Client Issues VMware Host Client might display incorrect descriptions for severity event states When you look in the VMware Host Client to see the descriptions of the severity event states of an ESXi host, they might differ from the descriptions you see by using Intelligent Platform Management Interface (IPMI) or Lenovo XClarity Controller (XCC). For example, in the VMware Host Client, the description of the severity event state for the PSU Sensors might be Transition to Non-critical from OK, while in the XCC and IPMI, the description is Transition to OK. Workaround: Verify the descriptions for severity event states by using the ESXCLI command esxcli hardware ipmi sdr list and Lenovo XCC. Security Features Issues If you use an RSA key size smaller than 2048 bits, RSA signature generation fails Starting from vSphere 8.0, ESXi uses the OpenSSL 3.0 FIPS provider. As part of the FIPS 186-4 requirement, the RSA key size must be at least 2048 bits for any signature generation, and signature generation with SHA1 is not supported. Workaround: Use RSA key size larger than 2048.
Original source - Feb 24, 2026
- Date parsed from source:Feb 24, 2026
- First seen by Releasebot:Nov 25, 2026
VMware vCenter Server by Broadcom
VMware vCenter 8.0 Update 3i Release Notes
VMware vCenter Server releases Update 3i with smarter file-based backup retention, connection checks, and clearer failure messages. The update also resolves issues across certificates, content libraries, storage, security, and service responsiveness.
VMware vCenter 8.0 Update 3i | 24 FEB 2026 | ISO Build 25197330 What's New This release contains bugfixes as listed in the Resolved Issues section. For vSphere Supervisor updates, see the vSphere Supervisor 8.0 Release Notes. For Photon OS updates, see VMware vCenter Server Appliance Photon OS Security Patches. vCenter 8.0 Update 3i adds the following enhancements to file-based backup and restore: - Backup retention triggers 1 hour before a scheduled backup. In previous releases, backup retention triggers at midnight and could fail if a backup is also scheduled for midnight. - Adds backup connection validations to test backup server connectivity before starting a backup. The validation identifies unsupported configurations on the backup server before the backup triggers. - Adds enhanced messages for backup failures when a reason can be identified. For example, instead of a generic message such as BackupManager encountered an exception. See logs for details. https://<hostname>/appliance/support-bundle, you see a message with details and specific recommendations, such as Failed to send data to the destination server. Check network connectivity permissions or available space on the server. See logs for details. https://<hostname>/appliance/support-bundle. Upgrade Notes An upgrade from vCenter 8.0 Update 3i to VCF 9.0.0.0, 9.0.1.0, or 9.0.2.0 is currently not supported but an upgrade path will be available with a future vCenter 8.x release. The upgrade is not supported due to the back-in-time release upgrade restriction. You can track back-in-time release information in the Interoperability Matrix. Patches Contained in This Release Patch for VMware vCenter 8.0 Update 3i This patch is applicable to vCenter Server. Download Filename: VMware-vCenter-Server-Appliance-8.0.3.00800-25197330-patch-FP.iso Build: 25197330 Download Size: 8449.6 MB sha256checksum: 11af69ddab2a284034d5bb5bddbc656e25adb74a5854a1d0496e57c8e07ead37 PRs fixed: 3646707, 3624342, 3629116, 3637735, 3613433, 3637106, 3561815, 3624112, 3624816, 3594811, 3631149, 3618455, 3602673, 3619112, 3593300, 3589071, 3621023 CVEs: N/A Download and Installation Log in to the Broadcom Support Portal to download this patch. See these KBs for details on the authenticated online and offline download: 390121, 390098, and 389276. For more information on using the vCenter Server shells, see VMware knowledge base article 2100508. For more information on patching vCenter Server, see Patching and Updating vCenter Server 8.0 Deployments. For more information on staging patches, see Upgrading the vCenter Server Appliance. Resolved Issues Miscellaneous Issues PR 3646707: Logs under /var/mail/root fill up the root partition of the vCenter appliance The space_utility script runs as a daily cron job and by default, if a mail is not configured, cron jobs capture script output and mail it to /var/mail/root. As a result, space_utility logs might quickly accrue and fill up the root partition. This issue is resolved in this release. The fix redirects the space_utility script output to a /var/log/vmware/applmgmt/space_util_cron.log file instead of /var/mail/root and deactivates the mail for this specific cron job. PR 3624342: You cannot deploy NSX edges from the NSX Manager, but ovf deployment directly from the vSphere Client succeeds While deploying NSX edges, NSX issues multiple connections to the vCenter vpxd service over the /sdk tunnel. If vpxd attempts to use TLS session resumption, connections fail. As a result, you cannot deploy NSX edges from the NSX Manager, but ovf deployment directly from the vSphere Client succeeds. This issue is resolved in this release. PR 3629116: Importing custom third-party signed certificates to replace existing certificates by using vSphere Certificate Manager CLI fails If you export the keys and CSRs to either /tmp or /var/tmp directory when creating custom third-party signed certificates by using the vSphere Certificate Manager CLI, importing such certificates to replace the existing certificates fails with an error such as: ERROR:: INVALID_KEY, the private key does not match the certificate. Please provide a valid certificate and Key pair. This issue is resolved in this release. With the fix, the certificate manager CLI utility rejects /tmp or /var/tmp directories for exporting generated keys and CSRs. Instead, you must use a different folder, such as /storage/core, to export the generated keys and CSRs. PR 3637735: When you filter on the list of parameters while editing the advanced parameters of virtual machines, parameter values might be misplaced When you right-click a virtual machine and select Edit Settings > Advanced Parameters, if you filter the list of parameters, you might see the attributes and values of parameters misplaced. This issue is resolved in this release. PR 3613433: You see increase in Storage Policy Service (SPS) logs After a vCenter upgrade, you might see an increase in the volume of log data generated by the SPS service due to compliance workflows that trigger periodically. Such logs are forwarded to VCF Operations for logs or to external log aggregation products. The logs are of type INFO and do not indicate any error in the environment. This issue is resolved in this release. The fix changes the SPS logs type from INFO to DEBUG to avoid log spew. vSphere Client and vCenter Issues PR 3637106: Improper handling of vCenter Certificate Management error messages might trigger security scanner alerts If you run a penetration test or use a security scanner in your vCenter environment, some errors from the vCenter Certificate Management might trigger alerts for potential vulnerability. This issue is resolved in the release. PR 3561815: While generating a vCenter log bundle collection by using VMware Skyline Health Diagnostics, you might see a core dump for the procps-ops package VMware Skyline Health Diagnostics uses the command /bin/ps auwwx --sort -rss to generate a log bundle for vCenter and if the command fails, you see a core dump for the procps-ops package. The issue does not impact the task or Skyline Health Diagnostics performance. This issue is resolved in this release. PR 3624112: Remote vCenter mount precheck fails when the parent datacenter of the vSAN datastore is in a subfolder When you mount a vSAN datastore from another vCenter instance, the precheck fails if the parent datacenter of the vSAN datastore is in a custom folder instead of the inventory root folder. The vSAN service expects a specific hierarchical path to validate the remote datastore that prevents the mount operation. This issue is resolved in this release. PR 3564965: The client vCenter cannot connect to a remote vCenter that uses a multi-certificate chain When the remote vCenter has a certificate chain with multiple certificates, the client vCenter fails to communicate with it. Datastore information might display incorrectly, and the remote datastores might not mount or unmount. VM I/O on already mounted datastores remains unaffected. This issue is resolved in this release. PR 3594811: In the vSphere Client, when you add the Memory Tiering column to the grid in the Hosts tab, some of the other columns are empty When you click Manage Columns at the bottom part of the Hosts pane and from the Show Columns select Memory Tiering, columns like Uptime and State show no values when the Memory Tiering column appears in the grid. You do not see any values for the empty columns in the grid data csv export as well. This issue is resolved in this release. PR 3631149: You see residual NSX configuration on ESX hosts Under certain upgrade or configuration scenarios, vCenter might retain stale NSX-related configuration for a proxy switch on some ESXi hosts. As a result, you cannot remove the NSX VIB from the host or re-enable NSX on the proxy switch. This issue is resolved in this release. PR 3618455: vCenter requests might become unresponsive due to a HTTP/2 thread deadlock in the vmacore library In rare cases, vCenter might become unresponsive to incoming requests due to a deadlock in the HTTP/2 stack of the vmacore library that might eventually block all available worker threads. vCenter services do not immediately fail, but running tasks and API calls start hanging or timing out. This issue is resolved in this release. If you have implemented the workaround from KB 424166, you can revert the changes for all vCenter services to which you have applied it. For example, for the vpxd service, run the command python /usr/lib/vmware-vpx/py/xmlcfg.py -f /etc/vmware-vpx/vpxd.cfg delete vmacore/http/http2/maxPooledStreams in the vCenter Appliance and restart the vpxd service with the command service-control --restart vpxd. PR 3624816: In vCenter Enhanced Linked Mode, you see duplicate security policies when editing or creating a content library When you create or edit a content library on a vCenter instance in Enhanced Linked Mode, when you click on Apply Security Policy, you might see duplicates in the list of selections. The issue occurs because the list shows the policies of all linked vCenter systems rather than just the list for the selected instance. This issue is resolved in this release. The fix makes sure you see only the security polices from the selected vCenter instance. PR 3602673: Tasks for cloning and export to a content library might fail if you restrict network packets that use plain text Content libraries create a Network File Copy (NFC) connection that uses plain text for operations such as cloning and exporting content to the library. If you restrict network packets that use plain text, with a firewall for example, such operations fail. This issue is resolved in this release. With the fix, content libraries enable SSL/TLS for NFC connections and NFC uses a secure encrypted channel. PR 3619112: Last Checked timestamp in the Virtual Appliance Management Interface (VAMI) Update tab does not change In the VAMI, when you select Check Update > Check CD ROM + URL or Check Update > Check CD ROM, if no updates are available or an error occurs, the Last Checked timestamp does not change. The Last Checked timestamp changes only when a new update is available or you re-select either of the paths. This issue is resolved in this release. The Last Checked timestamp updates even if no updates are available or any error occurs. PR 3593300: The vCenter service vpxd might fail when deleting a cluster with stale entries in the vCenter database If the migration of virtual machines across clusters fails or is canceled, a stale entry might remain in the destination cluster. If you try to delete the cluster, such stale entries in the vCenter database might cause the vCenter service vpxd due to fail. This issue is resolved in this release. This fix prevents stale entries in the destination database in case a VM migration fails or is canceled. Security Issues PR 3589071: vCenter does not allow a standard key provider to establish trust by using an ECDSA client certificate and a private key vCenter can successfully enable a standard key provider to establish trust by using an RSA client certificate and private key, but fails to do so with an ECDSA client certificate and private key. This issue is resolved in this release. vSphere High Availability Issues PR 3621023: In very rare cases, during turning off vSphere Fault Tolerance (FT) or an FT failover, the primary VM might fail In very rare cases, while Fault Tolerance is turning off or an FT failover triggers, the primary VM might fail. This issue is resolved in this release. Backup and Restore Issues PR 3583757: SSH File Transfer Protocol (SFTP) backups fail while creating a directory on a remote backup server Repeated re-connection to a remote backup server while trying to create a SSH tunnel might cause backup server to reject connections from vCenter. As a result, in the backup logs, you see an error such as Failure establishing ssh session: -43, Failed getting banner. This issue is resolved in this release. Known Issues from Previous Releases The release notes also document known installation, upgrade, migration, miscellaneous, networking, storage, vCenter Server and vSphere Client, virtual machine management, vSphere Lifecycle Manager, VMware Host Client, security features, and backup and restore issues from previous releases, including workarounds where available.
Original source - Jan 20, 2026
- Date parsed from source:Jan 20, 2026
- First seen by Releasebot:Nov 25, 2026
VMware vCenter Server by Broadcom
VMware vCenter 9.0.2.0
VMware vCenter Server releases 9.0.2 with default Supervisor Control Plane backups, automatic renewal of eligible vCenter and ESX SSL certificates, and fixes for login, VM deployment, service stability, storage, networking, and backup issues. The update also documents known upgrade and Auto Deploy limitations.
Introduction VMware vCenter 9.0.2.0 | 20 JAN 2026 | Build 25148086 Check for additions and updates to these release notes. What's New This release delivers fixes listed in the Resolved Issues section. For vSphere Supervisor updates, see the vSphere Supervisor Release Notes. For Photon OS updates, see VMware vCenter Appliance Photon OS Security Patches. Default Backup for Supervisor Control Plane in VAMI: Starting with vCenter 9.0.2, to ensure comprehensive disaster recovery, the Supervisor Control Plane backup is enabled by default within the Virtual Appliance Management Interface (VAMI). This capability ensures that critical Supervisor data is automatically backed up alongside vCenter, preventing potential recovery failures during restoration. Auto-renewal of vCenter Machine SSL and ESX SSL Certificates: Starting with VCF 9.0.2, SSL certificates that the VMware Certificate Authority (VMCA) issues for vCenter and ESX are automatically renewed near the expiration date. vCenter machine SSL certificates are automatically extended by 2 years when the expiration date is in less than 5 days. SSL certificates on ESX hosts that support non-disruptive certificate renewal are automatically extended by 5 years when the expiration date is in less than 10 days. If the VMCA certificate mode is set to custom, auto-renewal does not work, and you need to change the mode to vmca to activate the feature. Patches Contained in This Release VMware vCenter 9.0.2.0 Build Details Download Filename: VMware-vCenter-Server-Appliance-9.0.2.0.25148086-patch-FP.iso Build: 25148086 Download Size: 9167.6 MB SHA256 checksum: 4ad92bb538ce2e004ebec5fb2715bea0431e06af0074448857dfbb2e2694962b CVEs N/A Patch Download and Installation Log in to the Broadcom Support Portal to download this patch, depending on your entitlement, VMware vSphere Foundation or VMware Cloud Foundation. For download instructions, see Download Broadcom products and software. See these KBs for details on the authenticated online and offline download: 390121, 390098, and 389276. For details on updates and upgrades by using vSphere Lifecycle Manager, see About vSphere Lifecycle Manager and vSphere Lifecycle Manager Baselines and Images. You can also update ESX hosts without the use of vSphere Lifecycle Manager by using an image profile. To do this, you must manually download the patch offline bundle ZIP file or see the KB How to download ESXi ISO image for all releases including patch updates. For more information, see Getting Started with ESXCLI and the VMware ESX Upgrade guide. VMware vCenter 9.0.2.0 resolves the following issues: vCenter and vSphere Client Issues Log in to vCenter fails with an error for fetching identity providers A rare race condition between the Security Token Service (STS) and the VPXD service might cause logging in to vCenter to fail with An error occurred while fetching identity providers.... Virtual machine fails to power on with error No host is compatible with the virtual machine If you power off a VM after installing VMware Tools and later export the VM to an OVF file, deploying VMs by using such OVFs might fail with the error No host is compatible with the virtual machine. The issue occurs because VMware Tools might not keep the correct OS Guestinfo of the VM before the power off. Log in to a management vCenter by using VCF Single Sign-On (SSO) fails Logging in with a VCF Single Sign-On to the vCenter in a management or workload domain might fail with the error: [400] Unable to authenticate. Check your credentials. If problem persists, contact your administrator. The issue occurs due to expiration of the OAuth 2.0 client credentials due to a 90-day rotation. The vCenter vpxd service becomes unavailable after running an automation script to gather data from vCenter Running an automation script that calls VMODL1 Session Manager Login and then uses the created session in several parallel VMODL2 API calls can sometimes cause a failure of the vCenter vpxd service. vCenter does not allow a standard key provider to establish trust by using an ECDSA client certificate and a private key vCenter can successfully enable a standard key provider to establish trust by using an RSA client certificate and a private key, but fails to do so with an ECDSA client certificate and a private key. The vCenter service vpxd might fail when deleting a cluster with stale entries in the vCenter database If the migration of virtual machines across clusters fails or is canceled, a stale entry might remain in the destination cluster. If you try to delete the cluster, such stale entries in the vCenter database might cause the vCenter service vpxd to fail. This fix prevents stale entries in the destination database in case a VM migration fails or is canceled. Container volumes lose sync or disappear from vCenter If all ESX hosts are removed from one of the clusters that share a container volume, then vSphere Cloud Native Storage might remove the volume from the database even when the volume is accessible to other ESX hosts connected to a different datacenter. As a result, such volumes lose sync or disappear from vCenter. In the vSphere Client, you see the error "vCenter server replication status change alarm:" for vCenter instances in Enhanced Linked Mode (ELM) If the last operation in a replication task on a vCenter instance in ELM is a delete operation, such as deleting an existing user, a false replication health alarm might trigger. As a result, in the vSphere Client, you see the error vCenter server replication status change alarm: although the replication health is good. Auto Deploy Issues After replacing the ESX image in an Auto Deploy rule, the compliance check on ESX hosts fails with a username error In the vSphere Client, after you replace the ESX image in an Auto Deploy rule, when you select the host and click Check Compliance, the task might fail with the error Cannot complete login due to an incorrect user name or password. The issue occurs when the local OS domain configuration is missing or is set up improperly. Miscellaneous Issues You see increase in Storage Policy Service (SPS) logs After a vCenter upgrade, you might see an increase in the volume of log data generated by the SPS service due to compliance workflows that trigger periodically. Such logs are forwarded to VCF Operations for logs or to external log aggregation products. The logs are of type INFO and do not indicate any error in the environment. The fix changes the SPS logs type from INFO to DEBUG to avoid log spew. You see a Logical Switch State has failed alarm in the NSX user interface During reconfiguration of NSX logical switches, if some ESX hosts are disconnected from vCenter, the reconfiguration might fail and the alarm Logical Switch State has failed triggers in the NSX user interface. Distributed Power Management (DPM) operations take exceptionally long on HPE hosts When the option IPMI/DCMI over LAN access on HPE servers is deselected and HTTP port 80 is closed, DPM operations might take exceptionally long for ESX hosts on such servers. For example, Enter Standby Mode or Power On operations on a host might take an additional time of up to 40 minutes. Storage Issues You cannot create VM Storage Policy for tag-based placement using tag category and tags created by REST API calls When you create a tag for a VM Storage Policy for tag-based placement by using vMODL2 REST API calls, a tag category is successfully created, but tags of this category do not show as available options when configuring a new tag-based storage policy. Backup and Restore Issues vSphere Supervisor backup script might fail in time zones with a negative offset from UTC while requesting Holder-of-Key (HOK) tokens In time zones with a negative offset from UTC, such as UTC -7:00, the supervisors_backup_restore.py and wcp_backup_restore.py scripts might fail to get a HOK token by using a wcp service account such as [email protected], because the token confirmation certificate is expired. You see an errors such as raise TokenGenerationError("Failed to generate SAML token and \authentication.TokenGenerationError: Failed to generate SAML token. Networking Issues Distributed Virtual Switch (DVS) might go out of sync due to incorrect port–to-host associations In some cases, vCenter might push distributed switch ports to ESX hosts that are either connected to non-existing virtual machines or are not active. As a result, DVS falls into a continuous out-of-sync state. Known Issues vCenter and vSphere Client Issues After an upgrade, you do not see the Lifecycle Manager tab in the vSphere Client After an upgrade operation, you might not see the Lifecycle Manager tab in the vSphere Client or in the main menu. In the Tasks view, you see an error such as Error downloading plug-in. URL is unreachable. status code: 503, reason phrase: Service Unavailable VMware vSphere Lifecycle Manager. The issue occurs when immediately after the upgrade you log in to the vSphere Client before all the vCenter services, including the vSphere Lifecycle Manager backend service, are started. Workaround: Log out and log in to the vSphere Client. Remediation operations run in a single batch in large environments might fail due to ScanTask timeout In large environments, when remediation operations run in a single batch, you might see intermittent timeout errors during the host scanning phase. In the vSphere Client, you see errors such as: An internal error occurred while fetching the compliance result from the host XXXXXX. Failed to get task result for task(XXXXXX) on host(host-XXXX) : Dynamic exception type: VumVapi::Lib::VapiClient::wait_error std::exception::what: Operation timed out. The issue occurs not because any task fails, but because the status request waits in the queue longer than the 30-second threshold. Workaround: Retry the operation. Backup and Restore Issues SSH File Transfer Protocol (SFTP) backups fail while creating a directory on a remote backup server Repeated re-connection to a remote backup server while trying to create a SSH tunnel might cause backup server to reject connections from vCenter. As a result, in the backup logs, you see an error such as Failure establishing ssh session: -43, Failed getting banner. Workaround: See KB 399004. Upgrade Issues In rare cases, you cannot use ESX 8.0 Update 3e images for scanning, remediation, and stateful provisioning of hosts in vCenter 9.0.2 environment When you deploy vCenter 9.0.2, in rare cases, when your environment has no connectivity or no valid entitlement to access the online depot for ESX images, scanning, remediation, and stateful provisioning of hosts by using an ESX 8.0 Update 3e or ESX 8.0 Update 3es image might fail. In the vSphere Client, you see an error such as A general system error occurred: Cannot download VIB '/tmp/offlineBundlezmMaXC/vib20/loadesxio/VMware_bootbank_loadesxio_8.0.3-0.65.24659227.vib. The issue might also occur if the specified VIB does not exist or you do not have a properly set read privilege. Workaround: Make sure you download the required VIB before the upgrade and that your environment has connectivity. Sync your online depot or import an offline bundle for ESX 8.0 Update 3e image or later. Auto Deploy Issues You cannot use Auto Deploy with the NIST_2024 TLS profile If the iPXE infrastructure does not use the NIST-recommended TLS ciphers, Auto Deploy workloads might not comply with the NIST_2024 TLS profile. Workaround: Check with your server or iPXE vendor for compatibility.
Original source - Dec 15, 2025
- Date parsed from source:Dec 15, 2025
- First seen by Releasebot:Nov 25, 2026
VMware vCenter Server by Broadcom
VMware vCenter 8.0 Update 3h Release Notes
VMware vCenter Server releases Update 3h with clearer upgrade pre-check errors, a 50 GB default log partition, and automatic renewal of eligible VMCA-issued vCenter and ESXi certificates. It also resolves issues across vSphere services, networking, storage, upgrades, and more.
Introduction vCenter 8.0 Update 3h | 15 DEC 2025 | ISO Build 25092719 Check for additions and updates to these release notes. What's New This release contains bugfixes as listed in the Resolved Issues section. For vSphere Supervisor updates, see the vSphere Supervisor 8.0 Release Notes. For Photon OS updates, see VMware vCenter Server Appliance Photon OS Security Patches. Enhanced vCenter upgrade pre-check error messages: vCenter 8.0 Update 3h adds several enhanced upgrade pre-check error messages instead of a generic error message in the Virtual Appliance Management Interface. Messages for the following conditions provide specific information for the issue: - expired vCenter MACHINE_SSL certificate - available disk space - stopped vCenter core services - mismatch in the vCenter hostname and PIND - failure of the service startup for vCenter High Availability (VCHA) in instances with no active VCHA Default log partition of 50 GB: With vCenter 8.0 Update 3h, the default size of the log partition is 50 GB for any vCenter deployment. Auto-renewal of vCenter Machine SSL and ESXi SSL Certificates: Starting with vCenter 8.0 Update 3h, SSL certificates that the VMware Certificate Authority (VMCA) issues for vCenter and ESXi of version 8.0 Update 3 and later are automatically renewed near the expiration date. vCenter machine SSL certificates are automatically extended by 2 years when the expiration date is in less than 5 days. SSL certificates on ESXi hosts that support non-disruptive certificate renewal are automatically extended by 5 years when the expiration date is in less than 10 days. If the VMCA certificate mode is set to custom, auto-renewal does not work, and you need to change the mode to vmca to enable the feature. Patches Contained in This Release Patch for VMware vCenter Server 8.0 Update 3h This patch is applicable to vCenter Server. Download Filename: VMware-vCenter-Server-Appliance-8.0.3.00700-25092719-patch-FP.iso Build: 25092719 Download Size: 8336.1 MB sha256checksum: 84cd1563390b3b5b23923117c506144ec525218785d7ec0ac031f0f647dab245 PRs fixed: 3571785, 3565605, 3582332, 3512033, 3588267, 3594615, 3555318, 3574895, 3574892, 3551916, 3575427, 3556140, 3586423, 3487228, 3537457, 3528619, 3550634, 3554088, 3538803, 3531131, 3580735 CVEs: N/A Download and Installation Log in to the Broadcom Support Portal to download this patch. See these KBs for details on the authenticated online and offline download: 390121, 390098, and 389276. For more information on using the vCenter Server shells, see VMware knowledge base article 2100508. For more information on patching vCenter Server, see Patching and Updating vCenter Server 8.0 Deployments. For more information on staging patches, see Upgrading the vCenter Server Appliance. Resolved Issues This release resolves issues in Miscellaneous Issues, vSphere Client and vCenter Issues, Networking Issues, Upgrade Issues, vSAN Issues, Security Issues, Storage Issues, vSphere High Availability Issues, Auto Deploy Issues, and vSphere Lifecycle Manager Issues. Fixes include Distributed Power Management delays on HPE hosts; incorrect Workspace ONE Access syslog paths; VM power-on failures; VM Overrides page loading failures; missing DRS placement details; VAMI proxy connection errors; vSphere Configuration Profile certificate errors; missing log-partition warnings; false replication alarms; Summary page flickering; vpxd service failures; NSX logical switch alarms; scheduled-backup failures after password expiration; Web Console connection failures with SHA-1 disabled; false license-expiration warnings; manual backup errors; outdated or incorrectly retrieved VASA certificates; an incorrect Tbilisi time-zone index; DVS synchronization issues; generic upgrade errors; Workspace ONE container installation failures; missing vSAN health logs; federation-policy bypasses; disappearing container volumes; tag-based storage-policy creation failures; VCHA failovers; Auto Deploy performance and DNS failures; and vSphere Lifecycle Manager compatibility and service failures. Known Issues Known issues include SFTP backup failures, high memory usage in the automated space_cleanup utility, firewall requirements for port 9087, mixed-version DRS maintenance-mode failures, vSphere Lifecycle Manager compliance failures on ESXi 7.0 GA, update and upgrade warnings or failures, missing firmware compliance details, software FCoE host-profile validation errors, FIPS cipher requirements, VMNIC link issues, obsolete nmlx5_core parameters, DPU and remote-management behavior, DirectPath I/O hot-add and hot-remove limitations, Pensando DPU MTU and LLDP limitations, vSAN Storage vMotion failures, vSphere Client upload and scheduling issues, virtual-machine disk expansion failures, Lifecycle Manager reporting and remediation issues, VMware Host Client severity descriptions, and RSA signature failures with keys smaller than 2048 bits. Workarounds are provided where applicable.
Original source
Curated by the Releasebot team
Releasebot is an aggregator of official product update announcements from hundreds of software vendors and thousands of sources.
Our editorial process involves the manual review and audit of release notes procured with the help of automated systems.